AUTOMATIC-DETERMINATION OF INDOMETHACIN IN HUMAN PLASMA USING LIQUID-SOLID EXTRACTION ON DISPOSABLE CARTRIDGES IN COMBINATION WITH HPLC

被引:20
作者
HUBERT, P
CROMMEN, J
机构
[1] Laboratory of drug analysis, Institute of pharmacy, University of liege, Rue fusch, 5, b-4000, liege
来源
JOURNAL OF LIQUID CHROMATOGRAPHY | 1990年 / 13卷 / 19期
关键词
D O I
10.1080/01483919008049576
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive and automatic method for the analysis of indomethacin in plasma has been developed using liquid-solid extraction (LSE) on disposable extraction cartridges (DECs) coupled to high-performance liquid chromatography (HPLC). The fully automated system handles the plasma samples by performing the same operations as in a manuel procedure by means of an autosampler equipped with a robotic arm at which is attached a needle dispensing the different liquids. The DEC is first conditioned with methanol and phosphate buffer pH 7.4. A 1.0-mL volume of plasma is then applied onto the DEC; the latter is washed with the same buffer before the elution with 0.25 mL of methanol. The eluting strength of the eluate is reduced by dispensing 0.30 mL of phosphate buffer pH 7.4 in the collection tube prior to the injection onto the HPLC column via a 0.1-ml loop. The chromatographic separation is performed on an octadecylsilica column with a mixture of methanol and phosphate buffer pH 7.4 as mobile phase (60:40, v/v) and indomethacin is monitored photometrically at 254 nm. The effect of the plasma dispensing flow rate on the drug recovery and the importance of the guard column for the stability of the analytical column have been studied. The absolute recovery of the drug is 96.0 % and the limit of detection, 2 ng/mL. At the concentration of 100 ng/mL, relative standard deviations of 1.5 % (within-day) and 2.3 % (between-day) have been obtained.
引用
收藏
页码:3891 / 3907
页数:17
相关论文
共 21 条
  • [1] ASTIER A, 1982, J CHROMATOGR, V223, P279
  • [2] HIGH-PRESSURE LIQUID-CHROMATOGRAPHIC METHOD WITH POSTCOLUMN, IN-LINE HYDROLYSIS AND FLUOROMETRIC DETECTION FOR INDOMETHACIN IN BIOLOGICAL-FLUIDS
    BAYNE, WF
    EAST, T
    DYE, D
    [J]. JOURNAL OF PHARMACEUTICAL SCIENCES, 1981, 70 (04) : 458 - 459
  • [3] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY - FLUORESCENCE ANALYSIS FOR INDOMETHACIN AND METABOLITES IN BIOLOGICAL-FLUIDS
    BERNSTEIN, MS
    EVANS, MA
    [J]. JOURNAL OF CHROMATOGRAPHY, 1982, 229 (01): : 179 - 187
  • [4] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF INDOMETHACIN SERUM CONCENTRATIONS
    BROWN, YL
    KANDROTAS, RJ
    DOUGLAS, JB
    GAL, P
    [J]. JOURNAL OF CHROMATOGRAPHY, 1988, 459 : 275 - 279
  • [5] CLARK CR, 1987, J CHROMATOGR SCI, V25, P247
  • [6] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY OF INDOMETHACIN AND ITS APPLICATION IN PHARMACOKINETICS IN HEALTHY-VOLUNTEERS
    COOPER, JK
    MCKAY, G
    HAWES, EM
    MIDHA, KK
    [J]. JOURNAL OF CHROMATOGRAPHY, 1982, 233 (DEC): : 289 - 296
  • [7] HIGHLY SENSITIVE MEASUREMENT OF INDOMETHACIN USING A HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC TECHNIQUE COMBINED WITH POSTCOLUMN IN-LINE HYDROLYSIS
    DEZEEUW, D
    LEINFELDER, JL
    BRATER, DC
    [J]. JOURNAL OF CHROMATOGRAPHY, 1986, 380 (01): : 157 - 162
  • [8] FREI RW, 1984, SWISS CHEM, V6, P55
  • [9] A FULLY AUTOMATED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE DETERMINATION OF INDOMETHACIN IN PLASMA
    HUBERT, P
    RENSON, M
    CROMMEN, J
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1989, 7 (12) : 1819 - 1827
  • [10] HUBERT P, 1990, 2ND INT S PHARM BIOM