IDENTIFICATION AND QUANTITATION OF DRUGS OF ABUSE IN URINE USING THE GENERALIZED RANK ANNIHILATION METHOD OF CURVE RESOLUTION

被引:13
作者
LI, SS
GEMPERLINE, PJ
BRILEY, K
KAZMIERCZAK, S
机构
[1] E CAROLINA UNIV, DEPT CHEM, GREENVILLE, NC 27858 USA
[2] E CAROLINA UNIV, SCH MED, DEPT CLIN PATHOL & DIAGNOST MED, GREENVILLE, NC 27858 USA
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 1994年 / 655卷 / 02期
关键词
D O I
10.1016/0378-4347(94)00102-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A rapid analytical method which is of practical use for the identification and quantitation of drugs of abuse in urine using HPLC with a diode-array detection is described. Because the method utilizes mathematical resolution of partially resolved peaks, greatly simplified sample preparation procedures and very short run times can be used. The generalized rank annihilation method (GRAM) is used to eliminate response due to unknown background peaks and separate partially resolved peaks. An optimized gradient elution program was found for which morphine, phenylpropanolamine, ephedrine, benzoylecgonine, lidocaine, cocaine, diphenhydramine, nortriptyline, norpropoxyphene, nordiazepam, codeine, D-amphetamine, meperidine, and amitriptyline elute from the HPLC column in less than 8.5 min. A commercially available system for HPLC analysis of drugs of abuse is currently available, however, the commercially available system takes 21 min to complete its analysis. Two modified sample pre-treatment methods were also developed to simplify sample treatment procedures substantially. In this paper, The GRAM technique is shown to be extremely powerful in identifying drugs of abuse from large overlapping peaks.
引用
收藏
页码:213 / 223
页数:11
相关论文
共 20 条
[1]   STRATEGIES FOR ANALYZING DATA FROM VIDEO FLUOROMETRIC MONITORING OF LIQUID-CHROMATOGRAPHIC EFFLUENTS [J].
APPELLOF, CJ ;
DAVIDSON, ER .
ANALYTICAL CHEMISTRY, 1981, 53 (13) :2053-2056
[2]  
DIXON PF, 1976, HIGH PRESSURE LIQUID
[3]   MULTICHANNEL IMAGING SPECTROPHOTOMETER FOR DIRECT ANALYSIS OF MIXTURES ON THIN-LAYER CHROMATOGRAPHY PLATES [J].
GIANELLI, ML ;
BURNS, DH ;
CALLIS, JB ;
CHRISTIAN, GD ;
ANDERSEN, NH .
ANALYTICAL CHEMISTRY, 1983, 55 (12) :1858-1862
[4]  
HERCULES DM, 1977, CONT TOPICS ANAL CLI, V1
[5]   HY-PHEN-ATED METHODS [J].
HIRSCHFELD, T .
ANALYTICAL CHEMISTRY, 1980, 52 (02) :A297-&
[6]   APPLICATION OF THE METHOD OF RANK ANNIHILATION TO FLUORESCENT MULTICOMPONENT MIXTURES OF POLYNUCLEAR AROMATIC-HYDROCARBONS [J].
HO, CN ;
CHRISTIAN, GD ;
DAVIDSON, ER .
ANALYTICAL CHEMISTRY, 1980, 52 (07) :1071-1079
[7]   SIMULTANEOUS MULTICOMPONENT RANK ANNIHILATION AND APPLICATIONS TO MULTICOMPONENT FLUORESCENT DATA ACQUIRED BY THE VIDEO FLUOROMETER [J].
HO, CN ;
CHRISTIAN, GD ;
DAVIDSON, ER .
ANALYTICAL CHEMISTRY, 1981, 53 (01) :92-98
[8]   GENERALIZED RANK ANNIHILATION METHOD USING SIMILARITY TRANSFORMATIONS [J].
LI, SS ;
HAMILTON, JC ;
GEMPERLINE, PJ .
ANALYTICAL CHEMISTRY, 1992, 64 (06) :599-607
[9]   ELIMINATING COMPLEX EIGENVECTORS AND EIGENVALUES IN MULTIWAY ANALYSES USING THE DIRECT TRILINEAR DECOMPOSITION METHOD [J].
LI, SS ;
GEMPERLINE, PJ .
JOURNAL OF CHEMOMETRICS, 1993, 7 (02) :77-88
[10]   RAPID SCREENING FOR 100 BASIC DRUGS AND METABOLITES IN URINE USING CATION-EXCHANGE SOLID-PHASE EXTRACTION AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH DIODE-ARRAY DETECTION [J].
LOGAN, BK ;
STAFFORD, DT ;
TEBBETT, IR ;
MOORE, CM .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1990, 14 (03) :154-159