MORPHOLOGICAL DETERMINANTS OF ECHOCARDIOGRAPHIC PATTERNS OF MITRAL-VALVE SYSTOLIC ANTERIOR MOTION IN OBSTRUCTIVE HYPERTROPHIC CARDIOMYOPATHY

被引:98
作者
KLUES, HG
ROBERTS, WC
MARON, BJ
机构
[1] NHLBI,CARDIOL BRANCH,BLDG 10,ROOM 7B-15,BETHESDA,MD 20892
[2] NHLBI,CARDIOL BRANCH,BETHESDA,MD 20892
关键词
HYPERTROPHIC CARDIOMYOPATHY; MITRAL VALVE; SYSTOLIC ANTERIOR MOTION; SUBAORTIC OBSTRUCTION;
D O I
10.1161/01.CIR.87.5.1570
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. The morphological determinants of mitral valve systolic anterior motion (SAM) and obstruction to left ventricular outflow in patients within the broad clinical spectrum of hypertrophic cardiomyopathy (HCM) are not completely understood, particularly the contribution of mitral leaflet length and size. Methods and Results. To clarify this issue, mitral valve specimens from 43 patients with HCM and basal outflow obstruction were used to relate morphometric measurements of leaflet area to certain morphological and functional assessments of left ventricular outflow tract geometry and valvular motion obtained from echocardiograms in the same patients. Twenty-four patients (56%) had mitral valves of normal size (leaflet area <12.0 cm2) and 19 patients (44%) had enlarged and elongated valves (area greater-than-or-equal-to 12.0 cm2). Compared with normal-sized mitral valves, the enlarged valves were situated more posteriorly in a larger left ventricular outflow tract (cross-sectional area, 3.3+/-1.0 versus 1.9+/-0.7 cm2 for normal-sized valves; p<0.001) and also had greater systolic excursion of the anterior leaflet (16.2+/-4.5 versus 13.3+/-3.3 mm, p<0.02), usually with a distinctive sharp-angled bend and localized contact of the leaflet tip with ventricular septum (''typical'' SAM); this pattern of SAM was possible because the central and distal portions of the leaflet were relatively free of fibrous thickening. In contrast, normal-sized mitral valves were situated more anteriorally in a smaller left ventricular outflow tract and frequently showed a different mechanism of SAM and subaortic obstruction with relatively limited leaflet motion, absence of a sharp bend, and septal contact involving more substantial portions of the anterior leaflet and contiguous chordae (''atypical'' SAM); mitral-septal apposition was effected in large measure by posterior ventricular septal motion. This pattern of SAM was invariably associated with a more diffuse pattern of fibrous thickening. Conclusions. Patients with obstructive HCM show patterns of mitral valve SAM that are diverse and determined largely by the interrelation of left ventricular outflow tract geometry, the size and mobility of the mitral leaflets, and the presence and distribution of fibrous thickening.
引用
收藏
页码:1570 / 1579
页数:10
相关论文
共 52 条
[1]  
BJORK VO, 1969, J THORAC CARDIOVASC, V41, P659
[2]  
BRAUNWALD E, 1964, CIRCULATION, V30, P3
[3]  
BROCK R, 1957, Guys Hosp Rep, V106, P221
[4]   CHORDAL GEOMETRY DETERMINES THE SHAPE AND EXTENT OF SYSTOLIC ANTERIOR MITRAL MOTION - INVITRO STUDIES [J].
CAPE, EG ;
SIMONS, D ;
JIMOH, A ;
WEYMAN, AE ;
YOGANATHAN, AP ;
LEVINE, RA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 13 (06) :1438-1448
[5]   THE MYXOMATOUS MITRAL-VALVE AND SUDDEN-DEATH [J].
CHESLER, E ;
KING, RA ;
EDWARDS, JE .
CIRCULATION, 1983, 67 (03) :632-639
[6]   ECHOCARDIOGRAPHIC ANALYSIS OF VENTRICULAR SEPTAL DYNAMICS IN HYPERTROPHIC CARDIOMYOPATHY AND OTHER DISEASES [J].
CIRO, E ;
MAIONE, S ;
GIUNTA, A ;
MARON, BJ .
AMERICAN JOURNAL OF CARDIOLOGY, 1984, 53 (01) :187-193
[7]  
DAVIES MJ, 1978, BRIT HEART J, V40, P468
[8]   MORPHOLOGICAL COMPARISON OF PATIENTS WITH MITRAL-VALVE PROLAPSE WHO DIED SUDDENLY WITH PATIENTS WHO DIED FROM SEVERE VALVULAR DYSFUNCTION OR OTHER CONDITIONS [J].
DOLLAR, AL ;
ROBERTS, WC .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 17 (04) :921-931
[9]  
ELLIS JG, 1971, CHEST, V9, P378
[10]   MUSCULAR SUBVALVULAR AORTIC STENOSIS - ABNORMAL ANTERIOR MITRAL LEAFLET POSSIBLY PRIMARY FACTOR [J].
FIX, P ;
MOBERG, A ;
SODERBERG, H ;
KARNELL, J .
ACTA RADIOLOGICA-DIAGNOSIS, 1964, 2 (03) :177-&