Differentiation of cocaine from heroine body packs by computed tomography: Impact of different tube voltages and the dual-energy index

被引:17
作者
Leschka, Sebastian [1 ]
Fornaro, Juergen [1 ]
Laberke, Patrick [2 ]
Blum, Simon [2 ]
Alkadhi, Hatem [3 ]
Niederer, Ivo [4 ]
Meile, Christian [4 ]
Hibbeln, Dennis [1 ]
Hausmann, Roland [2 ]
Wildermuth, Simon [1 ]
Eisenhart, Daniel [2 ]
机构
[1] Gen Hosp, Inst Radiol, Rorschacherstr 95, CH-9007 St Gallen, Switzerland
[2] Gen Hosp, Inst Legal Med, St Gallen, Switzerland
[3] Univ Hosp, Inst Diagnost & Intervent Radiol, Zurich, Switzerland
[4] Forens Sci Serv Inc, St Gallen, Switzerland
关键词
Computed tomography; Body packer; Dual-energy; Drug-smuggling; Cocaine; Heroin;
D O I
10.1016/j.jofri.2013.03.041
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Objectives: To investigate the computed tomography (CT) attenuation values and the dual-energy index (DEI) of cocaine and heroin at different tube voltage settings in a phantom study. Materials and methods: Thirty-three hand-wrapped bodypacks prepared of heroin (n=17) and cocaine (n=16) at varying concentrations were submerged in a 28-cm water tank and imaged four times with a dual-source 64-detector row CT at peak tube voltage levels of 80 kVp, 100 kVp, 120 kVp, and 140 kVp. Tube current in each protocol was adjusted for a similar CT volume dose index of 8.0 mGy. Image noise and the CT attenuation values were measured in each drug container three times at each tube voltage level by two independent observers, and the DEI was calculated from measurements at 80 kVp and 140 kVp. Results: Image noise at the four tube voltage levels was similar (p=0.32). Intra- and interobserver agreement was good (r=0.89 to.93; p < 0.001). CT attenuation values were different between cocaine and heroin at any tube voltage and in the DEL (p < 0.01) with the smallest overlap of attenuation values between both drugs at 80 kVp and the DEL The drug concentration had a strong negative relationship with the DEI for heroin (r=0.67; p <0.01) but not for cocaine (r=0.15; p=023). Conclusions: CT attenuation values measured at low tube voltage level and using the DEL improve the differentiation of cocaine and heroin-containing bodypacks compared to measurements at higher tube voltage settings. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:46 / 50
页数:5
相关论文
共 18 条
[1]
Role of radiology in a national initiative to interdict drug smuggling: The Dutch experience [J].
Algra, Paul R. ;
Brogdon, Byron G. ;
Marugg, Roque C. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 189 (02) :331-336
[2]
Brogdon, 2011, BROGDONS FORENSIC RA, P311
[3]
Flach P.M., 2011, EUROPEAN J RADIOLOGY
[4]
Dual energy CT characterization of urinary calculi: Initial in vitro and clinical experience [J].
Graser, Anno ;
Johnson, Thorsten R. C. ;
Bader, Markus ;
Staehler, Michael ;
Haseke, Nicolas ;
Nikolaou, Konstantin ;
Reiser, Maximilian F. ;
Stief, Christian G. ;
Becker, Christoph R. .
INVESTIGATIVE RADIOLOGY, 2008, 43 (02) :112-119
[5]
Dual energy CT: preliminary observations and potential clinical applications in the abdomen [J].
Graser, Anno ;
Johnson, Thorsten R. C. ;
Chandarana, Hersh ;
Macari, Michael .
EUROPEAN RADIOLOGY, 2009, 19 (01) :13-23
[6]
Drug smuggling by body packing: what radiologists should know about it [J].
Hergan, K ;
Kofler, K ;
Oser, W .
EUROPEAN RADIOLOGY, 2004, 14 (04) :736-742
[7]
Material differentiation by dual energy CT: initial experience [J].
Johnson, Thorsten R. C. ;
Krauss, Bernhard ;
Sedlmair, Martin ;
Grasruck, Michael ;
Bruder, Herbert ;
Morhard, Dominik ;
Fink, Christian ;
Weckbach, Sabine ;
Lenhard, Miriam ;
Schmidt, Bernhard ;
Flohr, Thomas ;
Reiser, Maximilian F. ;
Becker, Christoph R. .
EUROPEAN RADIOLOGY, 2007, 17 (06) :1510-1517
[8]
Krug K.D., 1991, P 1 INT S EXPL DET T, V1, P282
[9]
Low-Dose Computed Tomography for the Detection of Cocaine Body Packs: Clinical Evaluation and Legal Issues [J].
Pache, G. ;
Einhaus, D. ;
Bulla, S. ;
Baumann, T. ;
Langer, M. ;
Blanke, P. .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2012, 184 (02) :122-129
[10]
Analysis of illicit cocaine and heroin samples seized in Luxembourg from 2005-2010 [J].
Schneider, Serge ;
Meys, Francoise .
FORENSIC SCIENCE INTERNATIONAL, 2011, 212 (1-3) :242-246