VOLTAMMETRIC BEHAVIOR OF SCREEN-PRINTED CARBON ELECTRODES, CHEMICALLY MODIFIED WITH SELECTED MEDIATORS, AND THEIR APPLICATION AS SENSORS FOR THE DETERMINATION OF REDUCED GLUTATHIONE

被引:72
作者
WRING, SA
HART, JP
BIRCH, BJ
机构
[1] BRISTOL POLYTECH,DEPT SCI,COLDHARBOUR LANE,BRISTOL BS16 1QY,ENGLAND
[2] UNILEVER RES LABS,SENSORS GRP,SHARNBROOK MK44 1LQ,BEDS,ENGLAND
关键词
SCREEN-PRINTED CARBON ELECTRODES; CHEMICALLY MODIFIED FERROCENE; PHTHALOCYANINE AND HEXACYANOFERRATE(III) MEDIATO; REDUCED GLUTATHIONE; CYCLIC VOLTAMMETRY; AMPEROMETRY;
D O I
10.1039/an9911600123
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The evaluation of screen-printed carbon electrodes, chemically modified with selected ferrocene, phthalocyanine and hexacyanoferrate(III) derivative mediators for the determination of reduced glutathione (GSH), is described. Cyclic voltammetry was used to investigate the effect of pH on the electrochemical behaviour of these mediators incorporated in the disposable electrodes. Values of the electron-transfer coefficient (alpha-n(a)) were calculated for the oxidation of the mediators in phosphate buffer solution and solutions containing 0.48 mmol dm-3 GSH. Amperometry in stirred solutions was used to construct hydrodynamic voltammograms for each of the modified electrodes; these voltammograms were used to elucidate their steady-state behaviour. Both electrochemical techniques were used to calculate the reduction in overpotential for the oxidation of GSH; these calculations were performed for all of the chemically modified electrodes. Amperometry in stirred solutions was used as the technique for quantitative measurements, to determine the calibration response factors (mu-A mmol-1 dm3) and limits of detection for selected mediators towards GSH. The appropriate applied potentials were selected by reference to the hydrodynamic waves; a range of values were investigated to find the potential that gave the maximum sensitivity. The most promising mediators were cobalt phthalocyanine, iron phthalocyanine and ferrocenecarbaldehyde.
引用
收藏
页码:123 / 129
页数:7
相关论文
共 24 条
[1]   AMPEROMETRIC ASSAY FOR THE KETONE-BODY 3-HYDROXYBUTYRATE [J].
BATCHELOR, MJ ;
GREEN, MJ ;
SKETCH, CL .
ANALYTICA CHIMICA ACTA, 1989, 221 (02) :289-294
[2]  
BENNETTO HP, 1987, INT ANAL, V8, P22
[3]   ACETAMINOPHEN HEPATOTOXICITY [J].
BLACK, M .
ANNUAL REVIEW OF MEDICINE, 1984, 35 :577-593
[4]  
CURELLO S, 1987, CLIN CHEM, V33, P1448
[5]  
EASTMAN RD, 1984, CLIN HAEMATOL, P126
[6]  
FREW J E, 1988, Analytical Proceedings, V25, P276
[7]   ELECTROCHEMICAL BIOSENSORS [J].
FREW, JE ;
HILL, HAO .
ANALYTICAL CHEMISTRY, 1987, 59 (15) :A933-&
[8]   AMPEROMETRIC BIOSENSOR FOR THE RAPID-DETERMINATION OF SALICYLATE IN WHOLE-BLOOD [J].
FREW, JE ;
BAYLIFF, SW ;
GIBBS, PNB ;
GREEN, MJ .
ANALYTICA CHIMICA ACTA, 1989, 224 (01) :39-46
[9]  
GALUS Z, 1976, FUNDAMENTALS ELECTRO, P237
[10]   DETERMINATION OF CYSTEINE AND GLUTATHIONE IN PLASMA AND BLOOD BY LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION USING A CHEMICALLY MODIFIED ELECTRODE CONTAINING COBALT PHTHALOCYANINE [J].
HALBERT, MK ;
BALDWIN, RP .
JOURNAL OF CHROMATOGRAPHY, 1985, 345 (01) :43-49