THEORETICAL-ANALYSIS OF AN IMPLANTABLE FORCE TRANSDUCER FOR TENDON AND LIGAMENT STRUCTURES

被引:30
作者
XU, WS
BUTLER, DL
STOUFFER, DC
GROOD, ES
GLOS, DL
机构
[1] Noyes-Giannestras Biomechanics Laboratory, Department of Aerospace Engineering and Engineering Mechanics, University of Cincinnati, Cincinnati, OH
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 1992年 / 114卷 / 02期
关键词
D O I
10.1115/1.2891368
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A mathematical model was developed for an implantable force transducer to be inserted within the midsubstance of a ligament or tendon. The model was generated by performing both equilibrium and strain-displacement analyses on a metallic, curved beam structure placed within a parallel-fibered tissue. The analysis permitted the transverse pressure acting between the device and fibers to be calculated along with peak device strain and sensitivity (ratio of strain output to axial tissue force). Transducer pressure and transducer strain were expressed in terms of nondimensionalized design factors. A parametric analysis of the key design factors was then performed. The transverse pressure was shown to vary little for large changes in these factors whereas device strain changed markedly. The analysis was verified by a bench test on an example device. Such a model permits a proposed design to be evaluated without having to conduct costly experiments.
引用
收藏
页码:170 / 177
页数:8
相关论文
共 17 条
  • [1] STRAIN-MEASUREMENT IN THE MEDIAL COLLATERAL LIGAMENT OF THE HUMAN KNEE - AN AUTOPSY STUDY
    ARMS, S
    BOYLE, J
    JOHNSON, R
    POPE, M
    [J]. JOURNAL OF BIOMECHANICS, 1983, 16 (07) : 491 - 496
  • [2] DESIGN AND PERFORMANCE OF A MODIFIED BUCKLE TRANSDUCER FOR THE MEASUREMENT OF LIGAMENT TENSION
    BARRY, D
    AHMED, AM
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1986, 108 (02): : 149 - 152
  • [3] BUTLER DL, 1989, ASME ADV BIOENG, V15, P111
  • [4] Carnahan B., 1969, APPL NUMERICAL METHO
  • [5] CHUN KJ, 1988, T ORTHOPAEDIC RES SO, V13, P82
  • [6] COOK RD, 1985, ADV MECHANICS MATERI
  • [7] CUMMINGS JF, T ORTHOPAEDIC RES SO, V16, P601
  • [8] DORSEY J, ERRORS STRAIN GAGE T
  • [9] EDWARDS RG, 1970, ASME, V92, P131
  • [10] EFFECTS OF GAMMA-IRRADIATION ON THE INITIAL MECHANICAL AND MATERIAL PROPERTIES OF GOAT BONE-PATELLAR TENDON-BONE ALLOGRAFTS
    GIBBONS, MJ
    BUTLER, DL
    GROOD, ES
    BYLSKIAUSTROW, DI
    LEVY, MS
    NOYES, FR
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 1991, 9 (02) : 209 - 218