A DOUBLE-BLIND EVALUATION OF SODIUM-GRADIENT HEMODIALYSIS

被引:66
作者
DAUGIRDAS, JT
ALKUDSI, RR
ING, TS
NORUSIS, MJ
机构
[1] HINES LOYOLA MED CTR, DEPT MED, MAYWOOD, IL USA
[2] RUSH PRESBYTERIAN ST LUKES MED CTR, DEPT PREVENT MED, CHICAGO, IL 60612 USA
关键词
D O I
10.1159/000166927
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
In a double-blind, crossover trial, 7 chronic hemodialysis patients underwent three 4-wk treatment periods. During 1 period, dialysate contained 135 meq/l Na. During another period, dialysate contained 143 meq/l Na. During the remaining period Na gradient dialysate was used, the Na concentration of which was decreased from 160 to 133 meq/l during each 4 h dialysis session. Ultrafiltration was performed at a constant rate to achieve a predetermined post-dialysis weight. Interdialytic weight gain, thirst, blood pressure control, and incidence of side effects were monitored. There was a significant difference in interdialytic weight gain for the 3 treatments (P = 0.005). Interdialytic weight gain using 135 meq/l Na dialysate (2.2 .+-. 0.9 kg, mean .+-. SD) was significantly less than that using either 143 meq/l Na dialysate (2.6 .+-. 0.8 kg) or Na gradient dialysate (2.8 .+-. 0.7 kg). Self-reported thirst tended to be less severe with 135 mgq/l Na dialysate than with 143 meq/l Na dialysate or with Na gradient dialysate, but changes in thirst were not statistically significant (P = 0.13). The incidence of intradialytic hypotensive episodes was comparable with the 3 levels of dialysate Na. The described Na gradient method apparently does not prevent the increased interdialytic weight gain and thirst seen with other forms of high-Na dialysis, and probably does not reduce the incidence of side effects.
引用
收藏
页码:163 / 168
页数:6
相关论文
共 19 条
[1]  
[Anonymous], SPSS UPDATE 7 9
[2]  
Boquin E, 1977, Proc Clin Dial Transplant Forum, V7, P48
[3]   HYDROSTATIC ULTRAFILTRATION DURING HEMODIALYSIS USING DECREASING SODIUM DIALYSATE [J].
CHEN, WT ;
ING, TS ;
DAUGIRDAS, JT ;
HUMAYUN, HM ;
BRESCIA, DJ ;
GANDHI, VC ;
HANO, JE ;
KHEIRBEK, AO .
ARTIFICIAL ORGANS, 1980, 4 (03) :187-191
[4]  
CHEN WT, 1979, ARTIF ORGANS, V3, P377
[5]  
DUMLER F, 1979, T AM SOC ART INT ORG, V25, P351
[6]  
LEVINE J, 1978, T AM SOC ART INT ORG, V24, P139
[7]   HEMODIAFILTRATION WITH SODIUM CONCENTRATION-CONTROLLED DIALYSATE [J].
MAEDA, K ;
SAITO, A ;
KAWAGUCHI, S ;
ASADA, A ;
NIWA, T ;
OHTA, K ;
KOBAYASHI, K .
ARTIFICIAL ORGANS, 1980, 4 (02) :121-124
[8]  
Ogden D A, 1978, Proc Clin Dial Transplant Forum, V8, P157
[9]   PREVENTION OF DIALYSIS DISEQUILIBRIUM SYNDROME BY USE OF HIGH SODIUM CONCENTRATION IN DIALYSATE [J].
PORT, FK ;
JOHNSON, WJ ;
KLASS, DW .
KIDNEY INTERNATIONAL, 1973, 3 (05) :327-333
[10]  
RAJA R, 1983, T AM SOC ART INT ORG, V29, P649