DESIGN AND SIMULATION OF CLOSED-LOOP ELECTRICAL-STIMULATION ORTHOSES FOR RESTORATION OF QUIET STANDING IN PARAPLEGIA

被引:59
作者
JAEGER, RJ [1 ]
机构
[1] UNIV CHICAGO,PRITZKER SCH MED,DEPT SURG,ORTHOPED SECT,CHICAGO,IL 60637
关键词
D O I
10.1016/0021-9290(86)90133-8
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
BIOMECHANICS
引用
收藏
页码:825 / 835
页数:11
相关论文
共 44 条
  • [1] STANDING-UP OF A HEALTHY SUBJECT AND A PARAPLEGIC PATIENT
    BAJD, T
    KRALJ, A
    TURK, R
    [J]. JOURNAL OF BIOMECHANICS, 1982, 15 (01) : 1 - 10
  • [2] FREQUENCY-RESPONSE OF HUMAN SOLEUS MUSCLE
    BAWA, P
    STEIN, RB
    [J]. JOURNAL OF NEUROPHYSIOLOGY, 1976, 39 (04) : 788 - 793
  • [3] Brunnstrom S, 1972, CLIN KINESIOLOGY, V3rd
  • [4] MUSCLE-SPINDLE ACTIVITY IN MAN DURING STANDING
    BURKE, D
    EKLUND, G
    [J]. ACTA PHYSIOLOGICA SCANDINAVICA, 1977, 100 (02): : 187 - 199
  • [5] CAPOZZO A, 1980, J BIOMECHANICS, V13, P231
  • [6] CHIZEK HJ, 1985, 8TH P ANN C REH ENG, P231
  • [7] LOWER-EXTREMITY BRACING IN PARAPLEGIA - FOLLOW-UP-STUDY
    COGHLAN, JK
    ROBINSON, CE
    NEWMARCH, B
    JACKSON, G
    [J]. PARAPLEGIA, 1980, 18 (01): : 25 - 32
  • [8] CLOSED-LOOP CONTROL OF FORCE DURING ELECTRICAL-STIMULATION OF MUSCLE
    CRAGO, PE
    MORTIMER, JT
    PECKHAM, PH
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1980, 27 (06) : 306 - 311
  • [9] LOWER-EXTREMITY FUNCTIONAL NEUROMUSCULAR STIMULATION IN CASES OF SPINAL-CORD INJURY
    CYBULSKI, GR
    PENN, RD
    JAEGER, RJ
    [J]. NEUROSURGERY, 1984, 15 (01) : 132 - 146
  • [10] CLONUS - THE ROLE OF CENTRAL MECHANISMS
    DIMITRIJEVIC, MR
    NATHAN, PW
    SHERWOOD, AM
    [J]. JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1980, 43 (04) : 321 - 332