INTRAAORTIC SPRING COIL LOOPS - EARLY AND LATE RESULTS

被引:25
作者
VERMA, R
LOCK, BG
PERRY, SB
MOORE, P
KEANE, JF
LOCK, JE
机构
[1] CHILDRENS HOSP, DEPT CARDIOL, BOSTON, MA 02115 USA
[2] NYU, MED CTR, DIV PEDIAT CARDIOL, NEW YORK, NY USA
关键词
D O I
10.1016/0735-1097(95)00015-V
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. Our aim was to determine the late fate of intraaortic spring coil loops after embolization of aortopulmonary vessels. Background. In some aortopulmonary collateral vessels and patent ductus arteriosi, the narrowest segment is close to the aorta; coils used to close such vessels will ''straddle'' the lesion, allowing one or more coil loops to protrude into the aortic lumen. The consequences of this procedure are unknown. Methods. We reviewed the cineangiograms of all patients who had at least one aortopulmonary collateral vessel or patent ductus arteriosus closure between January 1, 1988 and August 31, 1993. From this group, 53 patients had multiple-plane angiographic evidence of intraaortic coil loops. All subsequent cineangiograms were reviewed to determine coil position or movement and evidence of recanalization or endothelial coverage of the coil loop. We also reviewed each hospital record or communicated directly with referring physicians to identify any subsequent complications such as emboli or endocarditis. Results. Of the 53 patients with intraaortic coil loops, 49 patients had closure of one or more aortopulmonary collateral vessels (59 vessels), and 4 had closure of a patent ductus arteriosus (4 vessels). Patient follow-up ranged from 1 day to 66 months (median 20 months); follow-up was not available in 6 patients. Five of the 53 patients (9.3%; 95% confidence limits [CL] 3.1% to 20.7%) died at operation or of end stage heart failure. Patients with late angiography had no residual flow in 31 of 35 aortopulmonary collateral vessels (88.6%; 95% CL 73.3% to 96.8%), and 0.5 mm separated the coil and aortic contrast column in all 12 coils with adequate angiography, suggesting endothelial coverage of the intraaortic coil loop. No episodes of stroke, embolic events, endocarditis or coil migration were reported. Conclusions. Although coil occlusion of aortopulmonary collateral vessels or patent ductus arteriosi may produce intraaortic coil loops, endothelialization appears routine. No late complications associated with intraaortic coil loops were observed.
引用
收藏
页码:1416 / 1419
页数:4
相关论文
共 21 条
[1]  
Grinnell, Mehringer, Hieshima, Stanley, Lurie, Transaortic occlusion of collateral arteries to the lung by detachable valved balloons in a patient with tetratolgy of Fallot, Circulation, 65, pp. 1276-1278, (1982)
[2]  
Reidy, Jones, Tynan, Baker, Joseph, Embolisation procedures in congential heart disease, Br Heart J, 63, pp. 246-248, (1990)
[3]  
Florentine, Wolfe, White, Balloon embolization to occlude a Blalock-Taussig shunt, J Am Coll Cardiol, 3, pp. 200-202, (1984)
[4]  
Zuberbuhler, Anker, Zoltun, Burknoler, Bahnson, Tissue adhesive closure of aortic-pulmonary communications, Am Heart J, 88, pp. 41-46, (1974)
[5]  
Fuhrman, Bass, Castenada-Zuniga, Amplatz, Lock, Coil embolization of congenital thoracic vascular anomalies in infants and children, Circulation, 70, pp. 285-289, (1984)
[6]  
Perry, Radtke, Fellows, Keane, Lock, Coil embolization to occlude aortopulmonary collateral vessels and shunts in patients with congenital heart disease, J Am Coll Cardiol, 13, pp. 100-108, (1989)
[7]  
Anderson, Wallace, Gianturco, Gerson, “Mini” Gianturco stainless steel coils for transcatheter vascular occlusion, Radiology, 132, pp. 301-303, (1979)
[8]  
Lois, Gomes, Smith, Lass, Systemic-to-pulmonary collateral vessels and shunts treatment with embolization, Radiology, 169, pp. 671-676, (1988)
[9]  
Rothman, Tong, Percutaneous coil embolization of superfluous vascular connections in patients with congenital heart disease, Am Heart J, 126, pp. 206-213, (1993)
[10]  
Remy-Jardin, Wattinne, Remy, Transcatheter occlusion of pulmonary arterial circulation and collateral supply: failures. incidents, and complications, Radiology, 180, pp. 699-705, (1991)