MIC-III - AN INTEGRATED SOFTWARE PACKAGE TO SUPPORT EXPERIMENTS USING THE RADIOACTIVE MICROSPHERE TECHNIQUE

被引:32
作者
GROSS, W
SCHOSSER, R
MESSMER, K
机构
[1] Department of Experimental Surgery, University of Heidelberg, Heidelberg
关键词
Computer; Gamma spectrum analysis; Radioactive microsphere; Regional blood flow; Statistical analysis;
D O I
10.1016/0169-2607(90)90063-F
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
MIC-III is a versatile program system to support gamma spectrometry data management and data collection for experiments using the radioactive microsphere technique. It is mainly written in PASCAL and running on a minicomputer. Hierarchical organ dissection schemes are used for unique classification and identification of samples. For each series of experiments, up to 12 different nuclides and up to 20 different organ dissection schemes can be handled simultaneously. Sample weights are collected on-line and sample radioactivities are measured automatically by gamma spectrometry under process control. The spectra with a resolution of 1022 channels are analyzed using a modified linear regression technique and a strategy to compensate for global spectrum shifts. The spectrum deconvolution algorithm was evaluated by calculating the recovery indices for known nuclide mixtures and compared to the stripping method, matrix method and a linear regression technique using window counts. Recovery values produced by MIC-III are better balanced than those of the other methods. MIC-III showed the smallest dispersion of the recovery index and exhibited least error accumulation in case of spectrum shift. MIC-III computes regional blood flow and arterio-venous shunt, and provides interfaces to customized programs or statistical software packages for further analysis. It has successfully been employed in more than 140 experiments. © 1990.
引用
收藏
页码:65 / 85
页数:21
相关论文
共 19 条
[1]   MEASUREMENT OF CARDIAC-OUTPUT WITH AND ORGAN TRAPPING OF RADIOACTIVE MICROSPHERES [J].
ARCHIE, JP ;
FIXLER, DE ;
ULLYOT, DJ ;
HOFFMAN, JIE ;
UTLEY, JR ;
CARLSON, EL .
JOURNAL OF APPLIED PHYSIOLOGY, 1973, 35 (01) :148-154
[2]   INCREASED NUMBER OF MYOCARDIAL BLOOD-FLOW MEASUREMENTS WITH RADIONUCLIDE-LABELED MICROSPHERES [J].
BAER, RW ;
PAYNE, BD ;
VERRIER, ED ;
VLAHAKES, GJ ;
MOLODOWITCH, D ;
UHLIG, PN ;
HOFFMAN, JIE .
AMERICAN JOURNAL OF PHYSIOLOGY, 1984, 246 (03) :H418-H434
[3]  
DELMAESTRO RF, 1979, BIBL ANAT, V18, P201
[4]   PSEUDOCOLOR DISPLAY OF REGIONAL ORGAN BLOOD-FLOW DETERMINED BY MEANS OF THE RADIOACTIVE MICROSPHERE TECHNIQUE [J].
GROSS, W ;
ZELLER, P ;
KREIMEIER, U ;
MESSMER, K .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1990, 14 (01) :1-11
[5]   RADIOACTIVE MICROSPHERE MEASUREMENT OF CARDIAC-OUTPUT AND REGIONAL TISSUE BLOOD-FLOW IN SHEEP [J].
HALES, JRS .
PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1973, 344 (02) :119-132
[6]   BLOOD-FLOW MEASUREMENTS WITH RADIONUCLIDE-LABELED PARTICLES [J].
HEYMANN, MA ;
PAYNE, BD ;
HOFFMAN, JIE ;
RUDOLPH, AM .
PROGRESS IN CARDIOVASCULAR DISEASES, 1977, 20 (01) :55-79
[7]   COMPUTERIZED STRIPPING METHOD FOR MULTIPLE NUCLIDE MICROSPHERE STUDIES [J].
IRION, GL ;
WOLFSON, MR ;
ALSBERGE, MS .
COMPUTERS AND BIOMEDICAL RESEARCH, 1988, 21 (01) :27-37
[8]  
Knuth D.E., 1981, ART COMPUTER PROGRAM, V2
[9]  
Lawson C. J., 1974, SOLVING LEAST SQUARE
[10]   THE RADIOLABELED MICROSPHERE TECHNIQUE IN GUT BLOOD-FLOW MEASUREMENT - CURRENT PRACTICE [J].
LEVINE, BA ;
SIRINEK, KR ;
GASKILL, HV .
JOURNAL OF SURGICAL RESEARCH, 1984, 37 (03) :241-255