CARDIAC-OUTPUT BY PULSED DOPPLER IN NEONATES USING THE APICAL WINDOW

被引:26
作者
MANDELBAUMISKEN, VH [1 ]
LINDERKAMP, O [1 ]
机构
[1] UNIV HEIDELBERG,DIV NEONATOL,W-6900 HEIDELBERG,GERMANY
关键词
CARDIAC OUTPUT; DOPPLER ECHOCARDIOGRAPHY; NEONATES;
D O I
10.1007/BF02238491
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In 18 healthy neonates, cardiac output was measured by range-gated Doppler echocardiography with simultaneous two-dimensional echocardiography, using the apical approach. Maximal and modal flow velocities were compared by using spectral analysis of the Doppler signal. Blood flow velocities were measured in the left ventricular outflow tract and in the ascending aorta. Cardiac index (cardiac output per kg body weight), with the sample volume placed in the left ventricular outflow, averaged 170 +/- 45 ml/min/kg in the maximal flow velocity mode and 133 +/- 39 ml/min/kg in the modal mode, respectively (p < 0.05). Sampling in the ascending aorta gave cardiac index values of 198 +/- 73 ml/min/kg in the maximal velocity and 167 +/- 58 ml/min/kg in the modal velocity mode. Maximal flow velocities in the ascending aorta came closest to published data obtained by invasive and noninvasive methods.
引用
收藏
页码:13 / 16
页数:4
相关论文
共 15 条
[1]  
Alverson D C, 1984, Am J Perinatol, V1, P148, DOI 10.1055/s-2007-999991
[2]   EFFECT OF BOOSTER BLOOD-TRANSFUSIONS ON OXYGEN UTILIZATION IN INFANTS WITH BRONCHOPULMONARY DYSPLASIA [J].
ALVERSON, DC ;
ISKEN, VH ;
COHEN, RS .
JOURNAL OF PEDIATRICS, 1988, 113 (04) :722-726
[3]   EFFECT OF PATENT DUCTUS-ARTERIOSUS ON LEFT-VENTRICULAR OUTPUT IN PREMATURE-INFANTS [J].
ALVERSON, DC ;
ELDRIDGE, MW ;
JOHNSON, JD ;
BURSTEIN, R ;
PAPILE, L ;
DILLON, T ;
YABEK, S ;
BERMAN, W .
JOURNAL OF PEDIATRICS, 1983, 102 (05) :754-757
[4]  
EMMANOUILIDES GC, 1970, BIOL NEONATE, V15, P186
[5]   STUDIES ON MATURITY IN NEWBORN-INFANTS .9. FURTHER OBSERVATIONS ON USE OF EXTERNAL CHARACTERISTICS IN ESTIMATING GESTATIONAL AGE [J].
FINNSTROM, O .
ACTA PAEDIATRICA SCANDINAVICA, 1977, 66 (05) :601-604
[6]   REPRODUCIBILITY OF DOPPLER AORTIC BLOOD-FLOW MEASUREMENTS - STUDIES ON INTRAOBSERVER, INTEROBSERVER AND DAY-TO-DAY VARIABILITY IN NORMAL SUBJECTS [J].
GARDIN, JM ;
DABESTANI, A ;
MATIN, K ;
ALLFIE, A ;
RUSSELL, D ;
HENRY, WL .
AMERICAN JOURNAL OF CARDIOLOGY, 1984, 54 (08) :1092-1098
[7]  
GESSNER I, 1965, PEDIATRICS, V36, P752
[8]  
HATLE L, 1985, DOPPLER ULTRASOUND C, P306
[9]  
IHLEN H, 1984, BRIT HEART J, V51, P54
[10]   PULSED DOPPLER ECHOCARDIOGRAPHIC DETERMINATION OF STROKE VOLUME AND CARDIAC-OUTPUT - CLINICAL VALIDATION OF 2 NEW METHODS USING THE APICAL WINDOW [J].
LEWIS, JF ;
KUO, LC ;
NELSON, JG ;
LIMACHER, MC ;
QUINONES, MA .
CIRCULATION, 1984, 70 (03) :425-431