DEVELOPMENT AND VALIDATION OF AN AUTOMATED PARTICLE-ENHANCED NEPHELOMETRIC IMMUNOASSAY METHOD FOR THE MEASUREMENT OF HUMAN PLASMA C1Q

被引:7
作者
BORQUE, L [1 ]
OLIVAN, V [1 ]
IGUAZ, F [1 ]
机构
[1] HOSP SAN MILLAN,BIOQUIM LAB,E-26004 LOGRONO,SPAIN
关键词
PARTICLE IMMUNOASSAY; COMPLEMENT; HOMOGENEOUS IMMUNOASSAY;
D O I
10.1002/jcla.1860090505
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
We have developed a sensitive immunoassay based on latex particle agglutination for measuring C1q concentrations in human plasma. In this simple and fast particle-enhanced immunoassay, we used carboxylated latex particles (diameter 210 nm) covalently coated with F(ab')(2) fragments of anti-C1q antibodies. These particles are incubated with diluted sample (400-fold) for 6 min at room temperature, with the resulting agglutination quantified by measuring the change of light-scatter produced. The assay has been automated on the Behring nephelometer analyzer with a sampling rate of 150 samples/hr. This assay generates a standard curve in the range of 24-775 mg/L, showing intraassay and interassay precision of <8% and <10%, respectively. Dilution linearity was validated throughout the dynamic range of the assay. There were no interferences from bilirubin, Intralipid, haemoglobin, and rheumatoid factor. Results obtained in 45 clinical samples correlated well with those obtained by a commercial radial immunodiffusion method (r = 0.936), and with those obtained by the Behring immunoprecipitation nephelometric test (r = 0.950). The mean concentration in plasma from healthy subjects was 180 mg/L and the reference interval was from 128 to 237 mg/L. This latex nephelometric procedure is a convenient method and an interesting alternative to other immunoassays for routine measurement of human C1q. (C) 1995 Wiley-Liss, Inc.
引用
收藏
页码:302 / 307
页数:6
相关论文
共 23 条
[1]   ENZYME-LINKED IMMUNOSORBENT-ASSAY FOR CLQ IN HUMAN-SERUM BY USE OF MONOCLONAL-ANTIBODIES [J].
ANTES, U ;
HEINZ, HP ;
LOOS, M .
JOURNAL OF IMMUNOLOGICAL METHODS, 1984, 74 (02) :299-306
[2]   AUTOMATED LATEX NEPHELOMETRIC IMMUNOASSAY FOR THE MEASUREMENT OF SERUM LIPOPROTEIN(A) [J].
BORQUE, L ;
RUS, A ;
DELCURA, J ;
MASIDE, C ;
ESCANERO, J .
JOURNAL OF CLINICAL LABORATORY ANALYSIS, 1993, 7 (02) :105-110
[3]   QUANTITATIVE AUTOMATED LATEX NEPHELOMETRIC IMMUNOASSAY FOR DETERMINATION OF MYOGLOBIN IN HUMAN SERUM [J].
BORQUE, L ;
RUS, A ;
RUIZ, R .
JOURNAL OF CLINICAL LABORATORY ANALYSIS, 1991, 5 (03) :175-179
[4]  
BORQUE L, 1990, REV DIAG BIOL, V39, P160
[5]   C1Q PROTEIN OF HUMAN COMPLEMENT [J].
CALCOTT, MA ;
MULLEREB.HJ .
BIOCHEMISTRY, 1972, 11 (18) :3443-+
[6]  
CAMBIASO CL, 1988, CLIN CHEM, V34, P416
[7]  
DAVENPORT A, 1992, NEPHROL DIAL TRANSPL, V7, P391
[8]  
DELANGHE JR, 1990, CLIN CHEM, V36, P1675
[9]  
GLICK MR, 1986, CLIN CHEM, V32, P470
[10]   AUTOMATED NEPHELOMETRIC IMMUNOASSAYS WITH NOVEL SHELL CORE PARTICLES [J].
KAPMEYER, WH ;
PAULY, HE ;
TUENGLER, P .
JOURNAL OF CLINICAL LABORATORY ANALYSIS, 1988, 2 (02) :76-83