BRAIN EXCITABILITY AND ELECTROENCEPHALOGRAPHIC ACTIVATION - NONINVASIVE EVALUATION IN HEALTHY HUMANS VIA TRANSCRANIAL MAGNETIC STIMULATION

被引:111
作者
ROSSINI, PM [1 ]
DESIATO, MT [1 ]
LAVARONI, F [1 ]
CARAMIA, MD [1 ]
机构
[1] OSPED FATEBENEFRATELLI OFTALMICO, SEZ NEUROL, ISOLA TIBERINA, ROME, ITALY
关键词
BRAIN EXCITABILITY; CORTICOSPINAL TRACT; ELECTROENCEPHALOGRAM; H-REFLEX;
D O I
10.1016/0006-8993(91)91442-4
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Excitability changes of the central motor tracts as a function of the electroencephalographic (EEG) characteristics has been investigated in 10 healthy volunteers. Transcranial magnetic stimulation (TCS) was administered to the right motor cortex with an intensity 5-10% above threshold for the elicitation of motor evoked potentials (MEPs) in the left forearm muscles. Simultaneously, the right median nerve was stimulated to provoke an H-reflex in the forearm flexors and EEG activity was recorded from the left hemiscalp. Subjects were completely relaxed and were asked at random either to keep the eyes closed while maintaining mental inactivity (A) or to open their eyes and perform mental arithmetics (B). Latencies and amplitudes of MEPs and H-reflexes were statistically matched with the spectral content of the EEG. In condition A, MEPs of 119 +/- 61-mu-V, with up to 36% of missing responses and background EEG activity dominated by rhythms in the alpha range were found. In condition B, MEPs of 219 +/- 66-mu-V (P < 0.001), with < 16% of missing responses, 'blocking' of the background alpha rhythms, and a potentiation of the faster ones' relative power were observed. Changes of the H-reflex characteristics were neither statistically significant nor related to MEP amplitude and EEG spectral profile fluctuations.
引用
收藏
页码:111 / 119
页数:9
相关论文
共 49 条