DECORPORATION OF TH-228 FROM THE RAT BY 3,4,3-LIHOPO AND DTPA AFTER SIMULATED WOUND CONTAMINATION

被引:19
作者
STRADLING, GN
GRAY, SA
PEARCE, MJ
WILSON, I
MOODY, JC
BURGADA, R
DURBIN, PW
RAYMOND, KN
机构
[1] UNIV PARIS 06,CHIM ORGANOELEMENTS LAB,F-75252 PARIS,FRANCE
[2] UNIV CALIF BERKELEY,DEPT CHEM,BERKELEY,CA 94720
[3] UNIV CALIF BERKELEY,LAWRENCE BERKELEY LAB,BERKELEY,CA 94720
来源
HUMAN & EXPERIMENTAL TOXICOLOGY | 1995年 / 14卷 / 02期
关键词
WOUNDS; TH-228; NITRATE; RAT; 3,4,3-LIHOPO; DTPA;
D O I
10.1177/096032719501400202
中图分类号
R99 [毒物学(毒理学)];
学科分类号
100405 ;
摘要
1 With DTPA as a comparison, the siderophore analogue 3,4,3-LIHOPO has been examined for its ability to remove Th-228 nitrate from the rat after subcutaneous (sc) and intramuscular (im) injection to simulate wound contamination. The commencement of treatment was delayed 30 min, 6 h or 1 d and the animals killed at 7 d. 2 In all cases 3,4,3-LIHOPO was appreciably more effective than DTPA although the efficacy of treatment and the relative effectiveness of the ligands decreased rapidly with their delay in administration. 3 Optimum removal with bath ligands occurred when initial local administration at 30 min after exposure was followed by repeated intraperitoneal injection at 6 h, 1, 2 and 3 d. Under these conditions the body content of Th-228 was reduced to 20% of controls after sc injection and 15% after im injection. The corresponding values using repeated DTPA administration were 80% and 54%. 4 It is concluded that 3,4,3-LIHOPO represents, potentially, a considerable advance on DTPA, the current agent of choice for the treatment of wounds contaminated by Th-228.
引用
收藏
页码:165 / 169
页数:5
相关论文
共 18 条
[1]  
ALBERT RE, 1967, THORIUM ITS IND HYGI
[2]  
FRIEND PJ, 1992, 2ND P INT C UR HEX H, P137
[3]  
FRITSCH P, IN PRESS RAD PROTECT
[4]  
GRAY SA, IN PRESS RAD PROTECT
[5]  
Griffith W. C., 1980, PULMONARY TOXICOLOGY, P193
[6]  
International Commission on Radiological Protection, 2012, ANN ICRP ICRP PUBLIC
[7]   DETERMINATION OF PLUTONIUM IN BIOLOGICAL MATERIALS BY EXTRACTION AN DLIQUID SCINTILLATION COUNTING [J].
KEOUGH, RF ;
POWERS, GJ .
ANALYTICAL CHEMISTRY, 1970, 42 (03) :419-&
[8]   EFFICACY OF DIFFERENT DTPA TREATMENT SCHEDULES FOR REMOVAL OF TH-234 FROM SIMULATED WOUNDS IN RATS [J].
PETERWITT, E ;
VOLF, V .
INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 1984, 45 (01) :45-49
[9]   COMPARISON OF CA-DTPA AND ZN-DTPA IN REMOVING TH-234 FROM THE RAT [J].
PETERWITT, E ;
VOLF, V .
HEALTH PHYSICS, 1985, 49 (03) :395-403
[10]  
PETERWITT E, 1986, RADIOBIOLOGY RADIUM, P183