MRI FINDINGS IN SUBJECTS WITH BREAST IMPLANTS

被引:9
作者
FRANKEL, S
OCCHIPINTI, K
KAUFMAN, L
KRAMER, D
CARLSON, J
MINEYEV, M
ESHIMA, I
FRIEDENTHAL, R
机构
[1] UNIV CALIF SAN FRANCISCO,DEPT RADIOL,S SAN FRANCISCO,CA 94080
[2] UNIV CALIF SAN FRANCISCO,RADIOL IMAGING LAB,S SAN FRANCISCO,CA 94080
[3] MT ZION HOSP & MED CTR,DEPT PLAST SURG,S SAN FRANCISCO,CA
关键词
D O I
10.1097/00006534-199509001-00014
中图分类号
R61 [外科手术学];
学科分类号
摘要
One-hundred and nineteen implants were imaged in an open-sided low-field magnetic resonance imaging system. Thirty-four of these implants were removed, and postoperative reports were made available. We found a variety of signs associated with the implants, including internal structures, loss of saline in double-lumen implants. intracapsular and extracapsular fluid accumulations,, signal dropout regions most likely associated with calcifications, and debris and fluid in the silicone, as well as degradation of the silicone, disruptions of the capsule and bulging, and extracapsular silicone. Conclusions of intact versus ruptured were made on the basis of these findings and found to be confirmed in 32 of 34 cases, with 1 false-positive and 1 false-negative result. Based on MRI criteria for a broad sample of the population, 27 percent of the implants were considered ruptured.
引用
收藏
页码:852 / 859
页数:8
相关论文
共 7 条
[1]   DIAGNOSING BREAST IMPLANT RUPTURE WITH MR-IMAGING, US, AND MAMMOGRAPHY [J].
BERG, WA ;
CASKEY, CI ;
HAMPER, UM ;
ANDERSON, ND ;
CHANG, BW ;
SHETH, S ;
ZERHOUNI, EA ;
KUHLMAN, JE .
RADIOGRAPHICS, 1993, 13 (06) :1323-1336
[2]  
BREM RF, 1992, J COMPUT ASSIST TOMO, V16, P157
[3]   DIFFERENTIATION OF SILICONE GEL FROM WATER AND FAT IN MR PHASE IMAGING OF PROTONS AT 0.064-T [J].
DERBY, KA ;
FRANKEL, SD ;
KAUFMAN, L ;
KRAMER, DM ;
CARLSON, JW ;
MINEYEV, MI ;
OCCHIPINTI, KA ;
FRIEDENTHAL, R .
RADIOLOGY, 1993, 189 (02) :617-620
[4]   CHARACTERISTICS OF MAGNETIC-RESONANCE SEQUENCES USED FOR IMAGING SILICONE GEL, SALINE, AND GEL-SALINE IMPLANTS AT LOW-FIELD STRENGTHS [J].
FRANKEL, S ;
OCCHIPINTI, K ;
KAUFMAN, L ;
KRAMER, D ;
CARLSON, J ;
MINEYEV, M ;
FRIEDENTHAL, R .
INVESTIGATIVE RADIOLOGY, 1994, 29 (08) :781-786
[5]   SILICONE BREAST IMPLANTS INVIVO - MR IMAGING [J].
GORCZYCA, DP ;
SINHA, S ;
AHN, CY ;
DEBRUHL, ND ;
HAYES, MK ;
GAUSCHE, VR ;
SHAW, WW ;
BASSETT, LW .
RADIOLOGY, 1992, 185 (02) :407-410
[6]  
KAUFMAN L, 1990, MAGN RESON QUART, V5, P283
[7]   SELECTIVE MR IMAGING OF SILICONE WITH THE 3-POINT DIXON TECHNIQUE [J].
SCHNEIDER, E ;
CHAN, TW .
RADIOLOGY, 1993, 187 (01) :89-93