VAPOR GENERATION OF NONMETALS COUPLED TO MICROWAVE PLASMA-TORCH MASS-SPECTROMETRY

被引:20
作者
DUAN, YX
WU, M
JIN, QH
HIEFTJE, GM
机构
[1] INDIANA UNIV,DEPT CHEM,BLOOMINGTON,IN 47405
[2] JILIN UNIV,DEPT CHEM,CHANGCHUN 130023,PEOPLES R CHINA
关键词
NONMETAL; PLASMA-TORCH MASS SPECTROMETRY; VAPOR GENERATION;
D O I
10.1016/0584-8547(95)01306-Y
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A chemical vapor-generation (CVG) method is compared with solution nebulization for determination of nonmetals by microwave plasma-torch mass spectrometry (MPT-MS). In contrast to solution nebulization, the CVG approach produces volatile species that are more efficiently transported to the plasma and influence the discharge to a lesser extent; furthermore, it enables analyte species to be separated from the sample matrix and solvent, so the Likelihood of spectral interferences is lessened. The optimal operating conditions for generating sulfur, chlorine, bromine and iodine vapors have been determined, and several analytical characteristics (including linear dynamic range, detection limits and matrix effects) have been evaluated.;The detection limits for several nonmetal elements are in the range from low ng ml(-1) to high pg ml(-1), between one and three orders of magnitude better than those for the same elements obtained with an inductively coupled plasma on the same mass spectrometer. The linear dynamic range is between four and five orders of magnitude.
引用
收藏
页码:1095 / 1108
页数:14
相关论文
共 35 条
[1]   LASER ABLATION OF SOLIDS FOR ELEMENTAL ANALYSIS BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
ARROWSMITH, P .
ANALYTICAL CHEMISTRY, 1987, 59 (10) :1437-1444
[2]  
BROWN PG, 1989, J ANAL ATOM SPECTROM, V4, P763
[3]   FUNDAMENTAL-STUDIES OF THE SAMPLING PROCESS IN AN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETER .4. REPLACEMENT OF THE INDUCTIVELY COUPLED PLASMA WITH A HELIUM MICROWAVE-INDUCED PLASMA [J].
CHAMBERS, DM ;
CARNAHAN, JW ;
JIN, Q ;
HIEFTJE, GM .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1991, 46 (13) :1745-1765
[4]  
CHANG PL, 1992, ANAL SCI, V8, P443
[5]   INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY FOR ELEMENTAL ANALYSIS AND ISOTOPE RATIO DETERMINATIONS IN INDIVIDUAL ORGANIC-COMPOUNDS SEPARATED BY GAS-CHROMATOGRAPHY [J].
CHONG, NS ;
HOUK, RS .
APPLIED SPECTROSCOPY, 1987, 41 (01) :66-74
[6]  
DARKE SA, 1989, ANAL P, V26, P379
[7]   CHARACTERISTICS OF FLOW-INJECTION INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY FOR TRACE-METAL ANALYSIS [J].
DEAN, JR ;
EBDON, L ;
CREWS, HM ;
MASSEY, RC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (02) :349-354
[8]   LASER SOLID SAMPLING FOR INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
DENOYER, ER ;
FREDEEN, KJ ;
HAGER, JW .
ANALYTICAL CHEMISTRY, 1991, 63 (08) :A445-&
[9]  
DUAN Y, 1991, J NAT SCI JILIN U, P106
[10]  
DUAN Y, 1991, CHEM RES CHN U, V7, P245