QUANTITATIVE DUAL-ENERGY CORONARY ARTERIOGRAPHY

被引:18
作者
MOLLOI, SY
WEBER, DM
PEPPLER, WW
FOLTS, JD
MISTRETTA, CA
机构
[1] UNIV WISCONSIN,CTR CLIN SCI,DEPT MED PHYS,MADISON,WI 53706
[2] UNIV WISCONSIN,CTR CLIN SCI,DEPT MED,MADISON,WI 53706
[3] UNIV WISCONSIN,CTR CLIN SCI,DEPT RADIOL,MADISON,WI 53706
关键词
Digital subtraction angiography (DSA); Energy subtraction; Quantitative arteriography;
D O I
10.1097/00004424-199008000-00007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Subtraction techniques for digital cardiac imaging have been hampered by misregistration artifacts. The use of dual-energy imaging is being evaluated as a means for reducing these artifacts. Results reported previously indicate that the dual-energy technique may be useful for applications such as exercise ventriculography and general quantification tasks. The purpose of the current study is to investigate the use of dual-energy subtraction imaging for quantitative coronary arteriography. In vivo coronary vessel phantoms (0.2 to 7 mm2 in cross-sectional area) were used to study the potential advantages of tissue suppressed energy subtracted images over unsubtracted images for quantification of absolute vessel cross-sectional area when cardiac motion is present. Estimates of lumen cross-sectional area (N = 20) were determined using videodensitometric analysis of selected energy subtracted and unsubtracted images. Linear regression analysis of measured and actual cross-sectional area showed energy subtracted image data (slope = 1.06, intercept = 0.48 mm2, r = 0.99) to have improved accuracy (P < .05) and precision (P < .05) over unsubtracted image data (slope = 1.24, intercept = 1.07 mm2, r = 0.95). © Lippincott-Raven Publishers.
引用
收藏
页码:908 / 914
页数:7
相关论文
共 13 条
[1]   HYBRID SUBTRACTION FOR IMPROVED ARTERIOGRAPHY [J].
BRODY, WR .
RADIOLOGY, 1981, 141 (03) :828-831
[2]  
DOBBINS JT, 1983, P SOC PHOTO-OPT INST, V419, P111, DOI 10.1117/12.936013
[3]   REAL-TIME DIGITAL K-EDGE SUBTRACTION FLUOROSCOPY [J].
HOUK, TL ;
KRUGER, RA ;
MISTRETTA, CA ;
RIEDERER, SJ ;
SHAW, CG ;
LANCASTER, JC ;
FLEMMING, DC .
INVESTIGATIVE RADIOLOGY, 1979, 14 (04) :270-278
[5]   AUTOMATED QUANTITATIVE CORONARY ARTERIOGRAPHY - MORPHOLOGICAL AND PHYSIOLOGICAL VALIDATION IN VIVO OF A RAPID DIGITAL ANGIOGRAPHIC METHOD [J].
MANCINI, GBJ ;
SIMON, SB ;
MCGILLEM, MJ ;
LEFREE, MT ;
FRIEDMAN, HZ ;
VOGEL, RA .
CIRCULATION, 1987, 75 (02) :452-460
[6]   QUANTIFICATION TECHNIQUES FOR DUAL-ENERGY CARDIAC IMAGING [J].
MOLLOI, SY ;
MISTRETTA, CA .
MEDICAL PHYSICS, 1989, 16 (02) :209-217
[7]  
MOLLOI SY, 1987, THESIS U WISCONSIN M, P8
[8]  
Nalcioglu O., 1988, Machine Vision and Applications, V1, P155, DOI 10.1007/BF01213002
[9]  
PEPPLER WW, 1983, DIGITAL IMAGING CARD, P56
[10]   QUANTITATIVE DIGITAL SUBTRACTION CORONARY ANGIOGRAPHY USING VIDEODENSITOMETRY - AN INVIVO ANALYSIS [J].
SIMONS, MA ;
MUSKETT, AD ;
KRUGER, RA ;
KLAUSNER, SC ;
BURTON, NA ;
NELSON, JA .
INVESTIGATIVE RADIOLOGY, 1988, 23 (02) :98-106