IMPROVED ESTIMATION OF INDUCTION MACHINE PARAMETERS

被引:23
作者
AKBABA, M
TALEB, M
RUMELI, A
机构
[1] Electrical Engineering Department, University of Bahrain, Isa Town
[2] Electrical Engineering Department, Middle East Technical University, Ankara
关键词
INDUCTION MACHINES; PARAMETER ESTIMATION; PERFORMANCE ASSESSMENT; LEVENBERG-MARQUARDT ALGORITHM;
D O I
10.1016/0378-7796(95)00958-K
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Induction machine parameters are often estimated from no-load and blocked-rotor tests. At different machine operating points, the parameter values may vary because of the nonlinearities caused mainly by the skin effect and saturation. Some investigators have already published techniques to estimate the parameters more accurately. Their techniques are either complicated or involve many simplified assumptions and are valid only at specific points. This paper proposes a less complicated yet accurate technique by making use of on-load machine performance measurements as input data. The proposed technique is formulated in an iterative algorithm while making few assumptions. The results obtained clearly show the influence of the skin effect and saturation on the rotor resistance, magnetizing and leakage reactances. Handy expressions that can predict the machine parameters as functions of the slip are derived. Machine performance is calculated by using the estimated parameters. This performance is compared with the true measurements. Excellent agreement is encountered. The performance is also compared with that obtained from a recent published technique and the superiority of the proposed technique is noted.
引用
收藏
页码:65 / 73
页数:9
相关论文
共 15 条
[1]  
Akbaba, Effects of design parameters on transients in induction machines, Ph.D. Thesis, (1977)
[2]  
Norman, Induction motor locked saturation curves, Trans. AIEE, 53, pp. 536-541, (1934)
[3]  
Chang, Lloyd, Saturation effect of leakage reactance, Trans. AIEE, Part 3, 68, pp. 1144-1147, (1949)
[4]  
Agarwal, Alger, Saturation factor for the leakage reactance of induction motors, Trans. AIEE, Part 3, 80, pp. 1037-1042, (1961)
[5]  
Angst, Saturation factor for the leakage reactance of induction motors with skewed rotors, Trans. AIEE, Part 3, 82, pp. 716-725, (1963)
[6]  
Chalmers, Dodgson, Saturated leakage reactance of cage induction motors, Proceedings of the Institution of Electrical Engineers, 116, pp. 1395-1410, (1969)
[7]  
Birch, Butler, Permeance of closed-slot bridges and its effect on induction-motor-current computation, Proceedings of the Institution of Electrical Engineers, 118, pp. 169-172, (1971)
[8]  
Akbaba, Fakhro, Saturation effect in three phase induction motors, Electr. Mach. Power Syst., 12, pp. 179-183, (1987)
[9]  
Williamson, Begg, Calculation of the bar resistance and leakage reactance of cage rotor with closed slots, IEE Proc. B, 132, pp. 125-132, (1985)
[10]  
Lemaire-Semail, Bouillault, Razek, Modeling of vector controlled cage induction motor with FEM, IEE Proc. B, 138, pp. 297-302, (1991)