DEVELOPMENT OF GC CAPILLARY COLUMN FOR ISOMER-SPECIFIC SEPARATION OF TOXIC ISOMER OF PCDDS AND PCDFS IN ENVIRONMENTAL-SAMPLES

被引:1
作者
NAIKWADI, KP
KARASEK, FW
机构
[1] Department of Chemistry, University of Waterloo, Waterloo
关键词
2; 3; 7; 8-TCDD; isomer specific selectivity; Liquid crystal polysiloxane; polychlorinated dibenzo-p-dioxins;
D O I
10.1016/0045-6535(90)90287-4
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Analysis of polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) has been performed using gas chromatography mass spectrometry (GC-MS). Analysis of the most toxic isomers, in particular, 2,3,7,8-substituted PCDD/PCDF in the presence of other isomers requires a special isomer specific capillary column or high performance liquid chromatography (HPLC) fractionation prior to GC-MS analysis. Commercially available long (>50 m) polar columns can separate 2,3,7,8-TCDD from other tetra isomers. However, those columns are not satisfactory for the analyses of total PCDD/PCDF in the environmental samples. Gas chromatography -high resolution mass spectrometry (GC-HRMS) and GC-MS/MS techniques are not helpful in the analysis of 2,3,7,8-TCDD unless it is separated from the other tetra isomers. The analysis of 2,3,7,8-TCDD and total PCDD and PCDF in a single GC-MS run can ease the laborious techniques presently used. In this study we have developed a new stationary phase for the GC capillary column. The capillary column developed using this new stationary phase showed unsurpassed selectivity for the separation of 2,3,7,8-TCDD from other tetra isomers. There are several advantages of the newly developed GC capillary column. © 1990.
引用
收藏
页码:1379 / 1384
页数:6
相关论文
共 8 条
[1]  
BRADLAW JA, 1979, J ASSOC OFF ANA CHEM, V62, P904
[2]   CHLORINATED DIBENZO-PARA-DIOXINS (CDDS) AND DIBENZOFURANS (CDFS) IN EFFLUENTS AND SLUDGES FROM PULP AND PAPER-MILLS [J].
CLEMENT, RE ;
TASHIRO, C ;
SUTER, S ;
REINER, E ;
HOLLINGER, D .
CHEMOSPHERE, 1989, 18 (1-6) :1189-1197
[3]  
MUIR DCG, 1983, ENVIRON TOXICOL CHEM, V269, P2
[4]   USE OF C-13 LABELED DIOXINS MIXTURE FOR ANALYSIS OF POLYCHLORINATED DIBENZO-PARA-DIOXINS IN ENVIRONMENTAL-SAMPLES BY GC-MS [J].
NAIKWADI, KP ;
KARASEK, FW .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1990, 38 (03) :329-342
[5]  
NAIKWADI KP, 1990, IN PRESS CHROMATOGRA, V5, pCH24
[6]  
POLAND A, 1976, J BIOL CHEM, V251, P4926
[7]   MONITORING DIOXINS AND FURANS IN PRECIPITATION SAMPLES [J].
TASHIRO, C ;
CLEMENT, RE ;
LUSIS, M ;
ORR, D ;
REID, N .
CHEMOSPHERE, 1989, 18 (1-6) :777-782
[8]   HPLC CLEANUP PROCEDURES FOR THE DETERMINATION OF 2,3,7,8-TCDD IN FISH TISSUE [J].
THOMPSON, TS ;
SCHELLENBERG, DH ;
NAIKWADI, KP ;
KARASEK, FW .
CHEMOSPHERE, 1989, 19 (1-6) :45-50