A TEST OF REPRODUCIBILITY OF BLOOD-PRESSURE AND HEART-RATE-VARIABILITY USING A CONTROLLED AMBULATORY PROCEDURE

被引:47
作者
GERIN, W
ROSOFSKY, M
PIEPER, C
PICKERING, TG
机构
[1] HARVARD UNIV, SCH MED, BOSTON, MA 02115 USA
[2] DUKE UNIV, MED CTR, CTR AGING & HUMAN DEV, DURHAM, NC 27710 USA
关键词
AMBULATORY BLOOD PRESSURE MONITORING; RELIABILITY; REPRODUCIBILITY; BLOOD PRESSURE VARIABILITY; ROOT-MEAN-SQUARE OF SUCCESSIVE DIFFERENCES;
D O I
10.1097/00004872-199310000-00018
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objective: To determine whether the previously reported poor reproducibility of blood pressure variability measured by ambulatory blood pressure monitoring (ABPM) is due to the uncontrolled nature of physical and mental activity during the monitoring period. Design: ABPM was performed on two separate days during which subjects performed identical activities, accompanied by the experimenter. Thus, activity and posture were controlled, both within and between subjects. Two measures of variability were used: SD and the root-mean-square of successive differences (RMSSD). Methods: Thirty-seven subjects participated. Each engaged in a series of activities, such as walking outdoors, editing and alphabetizing tasks, and eating lunch, while wearing an A & D 2420 ambulatory blood pressure monitor which took measurements at 5-min intervals. Measures of variability were computed within each session. Results: Contrary to previous reports, reproducibility was moderately high for blood pressure, with significant correlations between SD and between RMSSD for systolic and diastolic blood pressure. Heart rate reproducibility was less good. Conclusions: Lack of standardization of activities from one occasion to another is a major reason for the poor reproducibility of blood pressure variability when measured using ABPM. Even when activities are standardized, however, the reproducibility of blood pressure variability is still only moderate and may limit the ability of researchers to detect associations between ABPM variability and other measures.
引用
收藏
页码:1127 / 1131
页数:5
相关论文
共 29 条
  • [1] BLOOD-PRESSURE AND HEART-RATE-VARIABILITY
    CONWAY, J
    [J]. JOURNAL OF HYPERTENSION, 1986, 4 (03) : 261 - 263
  • [2] CRONBACH LJ, 1972, DEPENDABILITY BEHAVI
  • [3] AMBULATORY BLOOD-PRESSURE RECORDINGS - REPRODUCIBILITY AND UNPREDICTABILITY
    DESCOMBES, BJ
    PORCHET, M
    WAEBER, B
    BRUNNER, HR
    [J]. HYPERTENSION, 1984, 6 (01) : 110 - 114
  • [4] LEFT-VENTRICULAR HYPERTROPHY IN PATIENTS WITH HYPERTENSION - IMPORTANCE OF BLOOD-PRESSURE RESPONSE TO REGULARLY RECURRING STRESS
    DEVEREUX, RB
    PICKERING, TG
    HARSHFIELD, GA
    KLEINERT, HD
    DENBY, L
    CLARK, L
    PREGIBON, D
    JASON, M
    KLEINER, B
    BORER, JS
    LARAGH, JH
    [J]. CIRCULATION, 1983, 68 (03) : 470 - 476
  • [5] CONTINUOUS VS INTERMITTENT BLOOD-PRESSURE MEASUREMENTS IN ESTIMATING 24-HOUR AVERAGE BLOOD-PRESSURE
    DIRIENZO, M
    GRASSI, G
    PEDOTTI, A
    MANCIA, G
    [J]. HYPERTENSION, 1983, 5 (02) : 264 - 269
  • [6] FITZGERALD DJ, 1984, AMBULATORY BLOOD PRE, P71
  • [7] CARDIOVASCULAR-RESPONSES IN THE LABORATORY AND IN THE NATURAL-ENVIRONMENT - IS BLOOD-PRESSURE REACTIVITY TO LABORATORY-INDUCED MENTAL STRESS RELATED TO AMBULATORY BLOOD-PRESSURE DURING EVERYDAY LIFE
    FREDRIKSON, M
    BLUMENTHAL, JA
    EVANS, DD
    SHERWOOD, A
    LIGHT, KC
    [J]. JOURNAL OF PSYCHOSOMATIC RESEARCH, 1989, 33 (06) : 753 - 762
  • [8] POSTURE, PLACE, AND MOOD EFFECTS ON AMBULATORY BLOOD-PRESSURE
    GELLMAN, M
    SPITZER, S
    IRONSON, G
    LLABRE, M
    SAAB, P
    PASIN, RD
    WEIDLER, DJ
    SCHNEIDERMAN, N
    [J]. PSYCHOPHYSIOLOGY, 1990, 27 (05) : 544 - 551
  • [9] MEASUREMENT RELIABILITY OF CARDIOVASCULAR REACTIVITY CHANGE SCORES - A COMPARISON OF INTERMITTENT AND CONTINUOUS METHODS OF ASSESSMENT
    GERIN, W
    PIEPER, C
    PICKERING, TG
    [J]. JOURNAL OF PSYCHOSOMATIC RESEARCH, 1993, 37 (05) : 493 - 501
  • [10] DO LABORATORY TESTS OF BLOOD-PRESSURE REACTIVITY PREDICT BLOOD-PRESSURE CHANGES DURING EVERYDAY LIFE
    HARSHFIELD, GA
    JAMES, GD
    SCHLUSSEL, Y
    BLANK, SG
    PICKERING, TG
    [J]. AMERICAN JOURNAL OF HYPERTENSION, 1988, 1 (02) : 168 - 174