THORIUM AND URANIUM DETERMINATIONS IN ACRYLIC BY NEUTRON-ACTIVATION ANALYSIS

被引:14
作者
JAGAM, P [1 ]
WANG, JX [1 ]
SIMPSON, JJ [1 ]
机构
[1] UNIV GUELPH,DEPT PHYS,GUELPH N1G 2W1,ONTARIO,CANADA
来源
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES | 1993年 / 171卷 / 02期
关键词
D O I
10.1007/BF02219853
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Improvements in the detection limits of thorium and uranium in acrylics by neutron activation analysis are described. The average of results from 10 g samples was found to be higher than the results from 450 g samples taken from the same acrylic sheet. Using eighteen large (450 g) samples from a single sheet of acrylic gave an average value of 3.2 +/- 0.3 pg/g thorium and 1.1 +/- 0.7 pg/g uranium. Interpretation of the results is discussed. Epithermal neutron activation with Cd shielded irradiations did not improve the detection sensitivity for thorium.