SPECT WITH HMPAO COMPARED TO PET WITH FDG IN HUNTINGTON DISEASE

被引:15
作者
BOECKER, H
KUWERT, T
LANGEN, KJ
LANGE, HW
CZECH, N
ZIEMONS, K
HERZOG, H
SHIKARE, S
WEINDL, A
FEINENDEGEN, LE
机构
[1] FORSCHUNGSZENTRUM JULICH, INST MED, D-52425 JULICH, GERMANY
[2] UNIV DUSSELDORF, DEPT NUCL MED, W-4000 DUSSELDORF, GERMANY
[3] NEUROL THERAPY CTR, DUSSELDORF, GERMANY
[4] TECH UNIV MUNICH, KLINIKUM RECHTS ISAR, DEPT NEUROL, W-8000 MUNICH, GERMANY
关键词
EMISSION COMPUTED TOMOGRAPHY; SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY; HUNTINGTON DISEASE;
D O I
10.1097/00004728-199407000-00005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: It is the aim of this study to compare the performance of 99(m)Tc-d, l-hexamethylpropyleneamine oxime (HMPAO) SPECT with that of [F-18]fluorodeoxyglucose (FDG) PET in detecting striatal dysfunction as it occurs in Huntington disease (HD). Materials and Methods: For the determination of regional cerebral glucose consumption, the PET camera PC-4096 was used; the cerebral uptake of HMPAO was measured using the three-head SPECT camera TRIAD. Eight patients with manifest HD, seven subjects at risk for HD, and nine normal individuals were included in the study. In both modalities data evaluation was performed using caudate-to-whole-slice (C/S) ratios. The patients' data were compared to 95% confidence intervals determined in the nine controls. Results: The PET and SPECT CIS values correlated significantly (n = 24; r = 0.87; p < 0.0001). The CIS values were significantly reduced in PET in all eight and in SPECT in seven of the eight HD patients studied. Five of the seven at-risk subjects had normal CIS values in PET and SPECT, one showed reduced C/S values in both diagnostic methods, and the remaining at-risk individual showed a reduced C/S value in PET only. Thus, concordant results between PET and SPECT were obtained in seven of eight patients and six of seven at-risk subjects studied, corresponding to an 87% accuracy of SPECT in the detection of striatal dysfunction as compared to the ''gold standard'' PET. Conclusion: With use of a multidetector camera, HMPAO-SPECT comes near the performance of FDG-PET in the diagnosis of striatal dysfunction as it occurs in HD.
引用
收藏
页码:542 / 548
页数:7
相关论文
共 52 条
[1]   STUDIES OF CENTRAL-NERVOUS-SYSTEM DISORDERS WITH SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY AND POSITRON EMISSION TOMOGRAPHY - EVOLUTION OVER THE PAST 2 DECADES [J].
ALAVI, A ;
HIRSCH, LJ .
SEMINARS IN NUCLEAR MEDICINE, 1991, 21 (01) :58-81
[2]  
BARON JC, 1982, J NUCL MED, V23, P391
[3]  
BERENT S, 1988, ANN NEUROL, V23, P531
[4]  
BORTZ J, 1985, LEHRBUCH STATISTIK S
[6]  
COUBES P, 1993, NEUROL RES, V15, P160
[7]   NONOXIDATIVE GLUCOSE CONSUMPTION DURING FOCAL PHYSIOLOGIC NEURAL ACTIVITY [J].
FOX, PT ;
RAICHLE, ME ;
MINTUN, MA ;
DENCE, C .
SCIENCE, 1988, 241 (4864) :462-464
[8]  
GEMMELL HG, 1990, J NUCL MED, V31, P1595
[9]   A COMPARISON OF NEUROLOGICAL, METABOLIC, STRUCTURAL, AND GENETIC EVALUATIONS IN PERSONS AT RISK FOR HUNTINGTONS-DISEASE [J].
GRAFTON, ST ;
MAZZIOTTA, JC ;
PAHL, JJ ;
STGEORGEHYSLOP, P ;
HAINES, JL ;
GUSELLA, J ;
HOFFMAN, JM ;
BAXTER, LR ;
PHELPS, ME .
ANNALS OF NEUROLOGY, 1990, 28 (05) :614-621
[10]  
HAMACHER K, 1986, J NUCL MED, V27, P235