NONITERATIVE COMPENSATION FOR THE DISTANCE-DEPENDENT DETECTOR RESPONSE AND PHOTON ATTENUATION IN SPECT IMAGING

被引:88
作者
GLICK, SJ [1 ]
PENNEY, BC [1 ]
KING, MA [1 ]
BYRNE, CL [1 ]
机构
[1] UNIV MASSACHUSETTS,LOWELL,MA
关键词
D O I
10.1109/42.293929
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
In this paper, a filtering approach is described, which accurately compensates for the 2D distance-dependent detector response, as well as for photon attenuation in a uniform attenuating medium. The filtering method is based on the frequency distance principle (FDP) which states that points in the object at a specific source-to-detector distance provide the most significant contribution to specified frequency regions in the discrete Fourier transform (DFT) of the sinogram. By modeling the detector point spread function as a 2D Gaussian function whose width is dependent on the source-to-detector distance, a spatially variant inverse filter can be computed and applied to the 3D DFT of the set of all sinogram slices. To minimize noise amplification the inverse filter is rolled off at high frequencies by using a previously published Wiener filter strategy. Attenuation compensation is performed with Bellini's method. It was observed that the tomographic point response, after distance-dependent filtering with the FDP, was approximately isotropic and varied substantially less with position than that obtained with other correction methods. Furthermore, it was shown that processing with this filtering technique provides reconstructions with minimal degradation in image fidelity.
引用
收藏
页码:363 / 374
页数:12
相关论文
共 33 条
  • [1] APPLEDORN CR, 1989, 1989 P INT C INF PRO, V363, P69
  • [2] COMPENSATION OF TISSUE ABSORPTION IN EMISSION TOMOGRAPHY
    BELLINI, S
    PIACENTINI, M
    CAFFORIO, C
    ROCCA, F
    [J]. IEEE TRANSACTIONS ON ACOUSTICS SPEECH AND SIGNAL PROCESSING, 1979, 27 (03): : 213 - 218
  • [4] Edholm P. R., 1986, Proceedings of the SPIE - The International Society for Optical Engineering, V671, P8, DOI 10.1117/12.966672
  • [5] THE EFFECT OF INTRINSIC ATTENUATION CORRECTION METHODS ON THE STATIONARITY OF THE 3-D MODULATION TRANSFER-FUNCTION OF SPECT
    GLICK, SJ
    HAWKINS, WG
    KING, MA
    PENNEY, BC
    SOARES, EJ
    BYRNE, CL
    [J]. MEDICAL PHYSICS, 1992, 19 (04) : 1105 - 1112
  • [6] AN INVESTIGATION OF THE STATIONARITY OF THE 3D MODULATION TRANSFER-FUNCTION OF SPECT
    GLICK, SJ
    KING, MA
    KNESAUREK, K
    BURBANK, K
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) : 973 - 977
  • [7] GOODMAN JW, 1976, SPIE SEMINAR P, V75, P141
  • [8] GREEN AJ, 1988, EUR J NUCL MED, V14, P226
  • [9] THE CIRCULAR HARMONIC TRANSFORM FOR SPECT RECONSTRUCTION AND BOUNDARY-CONDITIONS ON THE FOURIER-TRANSFORM OF THE SINOGRAM
    HAWKINS, WG
    LEICHNER, PK
    YANG, NC
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1988, 7 (02) : 135 - 148
  • [10] QUANTITATION IN POSITRON EMISSION COMPUTED-TOMOGRAPHY .1. EFFECT OF OBJECT SIZE
    HOFFMAN, EJ
    HUANG, SC
    PHELPS, ME