CONTRIBUTION OF IONICALLY IMMOBILIZED BOVINE SERUM-ALBUMIN TO THE RETENTION OF ENANTIOMERS

被引:22
作者
JACOBSON, SC
GUIOCHON, G
机构
[1] UNIV TENNESSEE,DEPT CHEM,KNOXVILLE,TN 37996
[2] OAK RIDGE NATL LAB,DIV ANALYT CHEM,OAK RIDGE,TN 37831
来源
JOURNAL OF CHROMATOGRAPHY | 1992年 / 600卷 / 01期
基金
美国国家科学基金会;
关键词
D O I
10.1016/0021-9673(92)85434-U
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The retention of the enantiomers of mandelic acid and N-benzoylalanine was studied on columns prepared by immobilizing bovine serum albumin (BSA) on an anion exchanger. The amount of BSA fixed on thc column is easy to adjust and measure. The adsorption isotherms were determined. For each enantiomer, the isotherm is well accounted for by a bi-Langmuir equation. One term of the isotherm (which is the same for both enantiomers) corresponds to non-selective interactions and the other term to the chiral selective interactions. The column saturation capacity of this second term is 8% larger for the less strongly retained enantiomer. This saturation capacity corresponds approximately to one enantiomer molecule adsorbed for five BSA molecules immobilized. This result is in agreement with the assumption of the hydrophobic cavity of BSA being the chiral selective site.
引用
收藏
页码:37 / 42
页数:6
相关论文
共 14 条
[1]   DIRECT LIQUID-CHROMATOGRAPHIC SEPARATION OF ENANTIOMERS ON IMMOBILIZED PROTEIN STATIONARY PHASES .4. MOLECULAR INTERACTION FORCES AND RETENTION BEHAVIOR IN CHROMATOGRAPHY ON BOVINE SERUM-ALBUMIN AS A STATIONARY PHASE [J].
ALLENMARK, S ;
BOMGREN, B ;
BOREN, H .
JOURNAL OF CHROMATOGRAPHY, 1984, 316 (DEC) :617-624
[2]   DIRECT RESOLUTION OF ENANTIOMERS BY LIQUID AFFINITY-CHROMATOGRAPHY ON ALBUMIN-AGAROSE UNDER ISOCRATIC CONDITIONS [J].
ALLENMARK, S ;
BOMGREN, B ;
BOREN, H .
JOURNAL OF CHROMATOGRAPHY, 1982, 237 (03) :473-477
[3]   DIRECT LIQUID-CHROMATOGRAPHIC SEPARATION OF ENANTIOMERS ON IMMOBILIZED PROTEIN STATIONARY PHASES .8. A COMPARISON OF A SERIES OF SORBENTS BASED ON BOVINE SERUM-ALBUMIN AND ITS FRAGMENTS [J].
ANDERSSON, S ;
ALLENMARK, S ;
ERLANDSSON, P ;
NILSSON, S .
JOURNAL OF CHROMATOGRAPHY, 1990, 498 (01) :81-91
[4]  
ARMSTRONG DW, 1988, CRIT REV ANAL CHEM, V19, P175
[5]   MESSUNG VON ADSORPTIONSISOTHERMEN AN KATALYSATOREN BEI HOHEN TEMPERATUREN MIT HILFE DER GAS-FESTKORPER-ELUIERUNGSCHROMATOGRAPHIE [J].
CREMER, E ;
HUBER, H .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 1961, 73 (13) :461-&
[6]   DIRECT ANALYTICAL AND PREPARATIVE RESOLUTION OF ENANTIOMERS USING ALBUMIN ADSORBED TO SILICA AS A STATIONARY PHASE [J].
ERLANDSSON, P ;
HANSSON, L ;
ISAKSSON, R .
JOURNAL OF CHROMATOGRAPHY, 1986, 370 (03) :475-483
[7]   COMPARISON BETWEEN EXPERIMENTAL AND THEORETICAL BAND PROFILES IN NONLINEAR LIQUID-CHROMATOGRAPHY WITH A PURE MOBILE PHASE [J].
GOLSHANSHIRAZI, S ;
GHODBANE, S ;
GUIOCHON, G .
ANALYTICAL CHEMISTRY, 1988, 60 (23) :2630-2634
[9]   CHROMATOGRAPHIC BAND PROFILES AND BAND SEPARATION OF ENANTIOMERS AT HIGH-CONCENTRATION [J].
JACOBSON, S ;
GOLSHANSHIRAZI, S ;
GUIOCHON, G .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1990, 112 (18) :6492-6498
[10]   EXPERIMENTAL-STUDY OF THE PRODUCTION-RATE OF PURE ENANTIOMERS FROM RACEMIC MIXTURES [J].
JACOBSON, SC ;
GUIOCHON, G .
JOURNAL OF CHROMATOGRAPHY, 1992, 590 (01) :119-126