THE EFFECT OF BONE MORPHOGENETIC PROTEIN ON OSSEOINTEGRATION OF TITANIUM IMPLANTS

被引:43
作者
XIANG, W
BAOLIN, L
YAN, J
YANG, X
机构
[1] NAVY GEN HOSP, DEPT DENT, BEIJING, PEOPLES R CHINA
[2] QIN DU STOMATOL COLL, DEPT ORAL MAXILLOFACIAL SURG, XIAN, PEOPLES R CHINA
[3] QIN DU STOMATOL COLL, DEPT ORAL PATHOL, XIAN, PEOPLES R CHINA
关键词
D O I
10.1016/S0278-2391(10)80264-2
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study evaluated the osteointegration of threaded cylindrical uncoated endosseous implants in combination with either bovine bone morphogenetic protein (bBMP) (group 1) or bovine serum albumin (BSA) (group 2) in edentulous dogs. Histologic observations showed that new bone formation was markedly increased by bBMP. The screw-surfaced implants in combination with bBMP exhibited apparent direct bone apposition 4 weeks postimplantation with no evidence of a connective tissue capsule. Thick fibrous connective tissue still encapsulated the control implants, although some new bone was observed slowly growing from the margins of the host bed. Eight weeks after implantation, there was an exact fit between the implant and the bone in group 1, and the surrounding bone was arranged in a regular manner. In group 2, there were still a few areas of thin fibrous tissue surrounding the implants. The results indicate that the rate of osteointegration was increased by bBMP. © 1993, American Association of Oral and Maxillofacial Surgeons.. All rights reserved.
引用
收藏
页码:647 / 651
页数:5
相关论文
共 16 条
[1]   DIRECT BONE ANCHORAGE OF DENTAL IMPLANTS [J].
ALBREKTSSON, T .
JOURNAL OF PROSTHETIC DENTISTRY, 1983, 50 (02) :255-261
[2]   FACTORS ASSOCIATED WITH SOFT-TISSUE AND HARD-TISSUE COMPROMISE OF ENDOSSEOUS IMPLANTS [J].
BLOCK, MS ;
KENT, JN .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1990, 48 (11) :1153-1160
[3]   CORRECTION OF ALVEOLAR RIDGE DEFORMITIES WITH TITANIUM IMPLANTS [J].
BLOCK, PL ;
WILEY, MG .
JOURNAL OF PROSTHETIC DENTISTRY, 1988, 60 (02) :221-225
[4]   OSSEOINTEGRATION AND ITS EXPERIMENTAL BACKGROUND [J].
BRANEMARK, PI .
JOURNAL OF PROSTHETIC DENTISTRY, 1983, 50 (03) :399-410
[5]  
HULTH A, 1988, CLIN ORTHOP RELAT R, V234, P235
[6]  
JOHNSON EE, 1990, CLIN ORTHOP RELAT R, P234
[7]   COMPARATIVE-STUDY OF HYDROXYAPATITE AND TITANIUM DENTAL IMPLANTS IN DOGS [J].
KOHRI, M ;
COOPER, EP ;
FERRACANE, JL ;
WAITE, DF .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1990, 48 (12) :1265-1273
[8]  
LOVELL TP, 1989, CLIN ORTHOP RELAT R, V243, P266
[9]   THREADED VERSUS POROUS-SURFACED DESIGNS FOR IMPLANT STABILIZATION IN BONE-ENDODONTIC IMPLANT MODEL [J].
MANIATOPOULOS, C ;
PILLIAR, RM ;
SMITH, DC .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1986, 20 (09) :1309-1333
[10]  
NILSSON O, 1985, CLIN ORTHOP RELAT R, P275