MRI CHARACTERIZATION OF DIFFUSION-COEFFICIENTS IN A RAT SPINAL-CORD INJURY MODEL

被引:143
作者
FORD, JC [1 ]
HACKNEY, DB [1 ]
ALSOP, DC [1 ]
JARA, H [1 ]
JOSEPH, PM [1 ]
HAND, CM [1 ]
BLACK, P [1 ]
机构
[1] HAHNEMANN UNIV,DEPT NEUROSURG,PHILADELPHIA,PA 19102
关键词
DIFFUSION; MAGNETIC RESONANCE IMAGING; SPINAL CORD INJURIES;
D O I
10.1002/mrm.1910310504
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Apparent diffusion coefficients (ADC) were measured in a rat spinal cord weight-drop injury model. After sacrifice, the spinal cords were fixed in situ and excised for MR imaging and ADC measurement. Diffusion is anisotropic in normal gray and white matter. There were significant decreases in ADCs measured along the longitudinal axis of the injured cord and increases in ADCs measured transverse to the cord. Injured segments demonstrated reductions in diffusion anisotropy in the white matter. Diffusion was completely isotropic at the epicenter of the weight drop injury. Significant decreases in longitudinal ADC and increases in transverse ADC were observed in portions of the cord which appeared normal on conventional spin-echo and calculated T-2 images. Thus ADC measurement may complement routine imaging for evaluation of spinal cord injury.
引用
收藏
页码:488 / 494
页数:7
相关论文
共 47 条
  • [1] ANDERSON A, 1993, 12TH P SMRM ANN M NE, P603
  • [2] MR IMAGING IN ACUTE CERVICAL-SPINE TRAUMA
    BEERS, GJ
    RAQUE, GH
    WAGNER, GG
    SHIELDS, CB
    NICHOLS, GR
    JOHNSON, JR
    MEYER, JE
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1988, 12 (05) : 755 - 761
  • [3] MECHANISM OF DETECTION OF ACUTE CEREBRAL-ISCHEMIA IN RATS BY DIFFUSION-WEIGHTED MAGNETIC-RESONANCE MICROSCOPY
    BENVENISTE, H
    HEDLUND, LW
    JOHNSON, GA
    [J]. STROKE, 1992, 23 (05) : 746 - 754
  • [4] MODELS OF SPINAL-CORD INJURY .3. DYNAMIC LOAD TECHNIQUE
    BLACK, P
    MARKOWITZ, RS
    DAMJANOV, I
    FINKELSTEIN, SD
    KUSHNER, H
    GILLESPIE, J
    FELDMAN, M
    [J]. NEUROSURGERY, 1988, 22 (01) : 51 - 60
  • [5] CARVLIN MJ, 1989, AM J NEURORADIOL, V10, P13
  • [6] ANISOTROPIC DIFFUSION IN HUMAN WHITE MATTER - DEMONSTRATION WITH MR TECHNIQUES INVIVO
    CHENEVERT, TL
    BRUNBERG, JA
    PIPE, JG
    [J]. RADIOLOGY, 1990, 177 (02) : 401 - 405
  • [7] Cotler H B, 1988, J Orthop Trauma, V2, P1, DOI 10.1097/00005131-198802000-00001
  • [8] NORMAL AND ABNORMAL WHITE MATTER TRACTS SHOWN BY MR IMAGING USING DIRECTIONAL DIFFUSION WEIGHTED SEQUENCES
    DORAN, M
    HAJNAL, JV
    VANBRUGGEN, N
    KING, MD
    YOUNG, IR
    BYDDER, GM
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1990, 14 (06) : 865 - 873
  • [9] MR COLOR MAPPING OF MYELIN FIBER ORIENTATION
    DOUEK, P
    TURNER, R
    PEKAR, J
    PATRONAS, N
    LEBIHAN, D
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1991, 15 (06) : 923 - 929
  • [10] MICROANGIOGRAPHIC STUDY OF EXPERIMENTAL SPINAL CORD INJURIES
    FAIRHOLM, DJ
    TURNBULL, IM
    [J]. JOURNAL OF NEUROSURGERY, 1971, 35 (03) : 277 - +