TEST-RETEST RELIABILITY OF ISOKINETIC KNEE EXTENSION AND FLEXION TORQUE MEASUREMENTS IN PERSONS WITH SPASTIC HEMIPARESIS

被引:32
作者
TRIPP, EJ [1 ]
HARRIS, SR [1 ]
机构
[1] UNIV WISCONSIN,SCH ALLIED HLTH PROFESS,THERAPEUT SCI PROGRAM,MADISON,WI 53706
来源
PHYSICAL THERAPY | 1991年 / 71卷 / 05期
关键词
HEMIPLEGIA; EVALUATION; MUSCLE PERFORMANCE; LOWER EXTREMITY; MUSCLE SPASTICITY;
D O I
10.1093/ptj/71.5.390
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of this study was to evaluate and compare the test-retest reliability of isokinetic torque measurements in the involved and uninvolved knee musculature of 20 subjects with spastic hemiparesis. An isokinetic dynamometer was used to measure maximal voluntary knee extension and flexion at 60-degrees and 120-degrees/s. Peak torque (PT) and average peak torque (APT) data were collected from five repetitions on two separate occasions. Average peak torque was defined as the mean of the PT values obtained during each of the five repetitions. Spasticity was measured in the involved knee musculature prior to isokinetic testing using the Ashworth Scale. Pearson Product-Moment Correlation Coefficients and intraclass correlation coefficients (ICCs) were high (greater-than-or-equal-to .90) for both knees for PT and APT at both angular velocities. No clinically meaningful differences were found between the Pearson correlation coefficients and the ICCs of the involved versus the uninvolved knee for any testing conditions. We concluded that isokinetic evaluation of torque, as measured by PT and APT in subjects with spastic hemiparesis, can yield reliable results in both extremities.
引用
收藏
页码:390 / 396
页数:7
相关论文
共 32 条
[1]   USING ISOKINETIC DYNAMOMETRY TO TEST AMBULATORY PATIENTS WITH MULTIPLE-SCLEROSIS [J].
ARMSTRONG, LE ;
WINANT, DM ;
SWASEY, PR ;
SEIDLE, ME ;
CARTER, AL ;
GEHLSEN, G .
PHYSICAL THERAPY, 1983, 63 (08) :1274-1279
[2]  
ASHWORTH B, 1964, PRACTITIONER, V192, P540
[3]  
Bobath B., 1978, ADULT HEMIPLEGIA EVA
[4]   RELATIONSHIP BETWEEN STATIC MUSCLE STRENGTH DEFICITS AND SPASTICITY IN STROKE PATIENTS WITH HEMIPARESIS [J].
BOHANNON, RW ;
LARKIN, PA ;
SMITH, MB ;
HORTON, MG .
PHYSICAL THERAPY, 1987, 67 (07) :1068-1071
[5]   KNEE EXTENSION TORQUE DURING REPEATED KNEE EXTENSION-FLEXION REVERSALS AND SEPARATED KNEE EXTENSION-FLEXION DYADS [J].
BOHANNON, RW .
PHYSICAL THERAPY, 1985, 65 (07) :1052-1054
[6]  
Brunnstrom S., 1970, MOVEMENT THERAPY HEM
[7]  
Carr JH, 1980, PHYSIOTHERAPY DISORD
[8]   FORCE-TIME MEASUREMENTS OF KNEE MUSCLE FUNCTIONS OF SUBJECTS WITH MULTIPLE-SCLEROSIS [J].
CHEN, WY ;
PIERSON, FM ;
BURNETT, CN .
PHYSICAL THERAPY, 1987, 67 (06) :934-940
[10]  
Davies GJ, 1984, COMPENDIUM ISOKINETI, V1st