HEAT AND MOISTURE EXCHANGERS WITH BACTERIAL FILTERS - A LABORATORY EVALUATION

被引:35
作者
MEBIUS, C
机构
[1] SABBATSBERGS HOSP, DEPT ANESTHESIOL, S-11382 STOCKHOLM, SWEDEN
[2] SABBATSBERGS HOSP, INTENS CARE UNIT, S-11382 STOCKHOLM, SWEDEN
关键词
BACTERIAL FILTER; HUMIDIFIER; MECHANICAL VENTILATION; RESPIRATORY THERAPY; WATER LOSS;
D O I
10.1111/j.1399-6576.1992.tb03521.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Six commercially available heat-moisture exchanger (HME) humidifiers with built-in bacterial filtration were evaluated by laboratory tests. Physical characteristics, humidification efficiency, resistance to flow and filtration capability were investigated. The resistance was comparable for all units and did not change notably with exposure to humidity. Deadspace values were in the range 55-92 ml and weight values between 34-55 g. The humidification efficiency of two units (Group 1) was clearly less (54%-63% at 1 1 tidal volume), than for the other four devices (Group 2) (77%-82%). This corresponds to an average humidification output of 22.0 g/m3 for Group 1 as compared to an output of 29.9 g/m3 for Group 2. The average filtration capability of Group 1 was 99.9998%, which is somewhat higher than the 99.9973% obtained for Group 2. There are significant differences between the humidification efficiency and deadspace of different units, with the Pall Conserve device having the least satisfactory performance. All units exhibit good filtering properties, with the Pall Conserve device performing best in this respect.
引用
收藏
页码:572 / 576
页数:5
相关论文
共 20 条
[1]  
BETHUNE DW, 1989, INTENSIVE CRIT CARE, V8, P37
[2]  
CIGADA M, 1990, INTENSIVE CARE WORLD, V7, P98
[3]   ENDOTRACHEAL-TUBE OCCLUSION ASSOCIATED WITH THE USE OF HEAT AND MOISTURE EXCHANGERS IN THE INTENSIVE-CARE UNIT [J].
COHEN, IL ;
WEINBERG, PF ;
FEIN, IA ;
ROWINSKI, GS .
CRITICAL CARE MEDICINE, 1988, 16 (03) :277-279
[4]   PERFORMANCE EVALUATION OF 6 HEAT AND MOISTURE EXCHANGERS ACCORDING TO THE DRAFT INTERNATIONAL STANDARD (ISO DIS-9360) [J].
ECKERBOM, B ;
LINDHOLM, CE .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1990, 34 (05) :404-409
[5]   HYGROSCOPIC CONDENSER HUMIDIFIER - NEW DEVICE FOR GENERAL USE IN ANESTHESIA AND INTENSIVE-CARE [J].
GEDEON, A ;
MEBIUS, C .
ANAESTHESIA, 1979, 34 (10) :1043-1047
[6]   NEONATAL HYGROSCOPIC CONDENSER HUMIDIFIER [J].
GEDEON, A ;
MEBIUS, C ;
PALMER, K .
CRITICAL CARE MEDICINE, 1987, 15 (01) :51-54
[7]   HYGROSCOPIC CONDENSER HUMIDIFIERS - VALUE FOR MONEY [J].
GILSTON, A .
ANAESTHESIA, 1984, 39 (10) :1030-1031
[8]  
KLAMBURG J, 1986, MED INTENSIVA, V10, P57
[9]  
LATHAM MJ, BM2044 PALL EUR LTD
[10]   PULMONARY-FUNCTION IN MECHANICALLY VENTILATED PATIENTS DURING 24 HOUR USE OF A HYGROSCOPIC CONDENSER HUMIDIFIER [J].
MACINTYRE, NR ;
ANDERSON, HR ;
SILVER, RM ;
SCHULER, FR ;
COLEMAN, RE .
CHEST, 1983, 84 (05) :560-564