MEASUREMENT OF EXTRAVASCULAR LUNG WATER BY THERMAL-DYE DILUTION TECHNIQUE - MECHANISMS OF CARDIAC-OUTPUT DEPENDENCE

被引:11
作者
WICKERTS, CJ
JAKOBSSON, J
FROSTELL, C
HEDENSTIERNA, G
机构
[1] UNIV HOSP UPPSALA,DEPT CLIN PHYSIOL,S-75185 UPPSALA,SWEDEN
[2] DANDERYD HOSP,DEPT ANAESTHESIA,S-18288 DANDERYD,SWEDEN
关键词
D O I
10.1007/BF01699857
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The extent to which extravascular lung water (EVLW) is dependent on cardiac output was analysed in anaesthetized and mechanically ventilated pigs. EVLW was measured by thermal-dye dilution technique, by a fibreoptic thermistor catheter system (system 1), and by a thermistor catheter-external optical cuvette system (system 2). During baseline conditions, at which cardiac output was 3.65 l/min, EVLW was 11.7 and 7.7 ml/kg b. w. with systems 1 and 2 respectively. A reduction of cardiac output to a mean of 1.90 l/min by the addition of halothane to the inspired gas did not significantly affect EVLW with system 1 (-5%) but increased EVLW by 39% (p < 0.05) with system 2. An increase of cardiac output to a mean of 4.78 l/min by intravenous infusion of isoproterenol caused a small increase in EVLW with system 1 (14%; p < 0.05) and a decrease with system 2 (10%; p < 0.05). The dependence on cardiac output was the same whether the catheters were positioned centrally (aortic root) or peripherally (abdominal aorta). With system 1 the CO dependence was due to different time constants in thermistor and optical systems, and with appropriate phasing the dependence could be eliminated. With system 2 a large overestimation of the mean transit time difference between the two indicators was seen when cardiac output was low, resulting in overestimation of EVLW. It is concluded that the dependence of EVLW volume on cardiac output is an artefact due to technical problems in the design of the recording equipment rather than a reflection of pulmonary or vascular effects.
引用
收藏
页码:115 / 120
页数:6
相关论文
共 8 条
[1]   EFFECT OF CARDIAC-OUTPUT ON EXTRAVASCULAR LUNG WATER ESTIMATES MADE WITH THE EDWARDS LUNG WATER COMPUTER [J].
FALLON, KD ;
DRAKE, RE ;
LAINE, GA ;
GABEL, JC .
ANESTHESIOLOGY, 1985, 62 (04) :505-508
[2]   EFFECTS OF PEEP ON EXTRAVASCULAR LUNG WATER AND CENTRAL BLOOD-VOLUME IN THE DOG [J].
FROSTELL, C ;
BLOMQVIST, H ;
WICKERTS, CJ .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1987, 31 (08) :711-716
[3]  
GOODWIN CW, 1982, SURGERY, V92, P401
[4]   THE MEASUREMENT OF EXTRA-VASCULAR LUNG WATER BY THERMAL-GREEN DYE INDICATOR DILUTION [J].
LEWIS, FR ;
ELINGS, VB ;
HILL, SL ;
CHRISTENSEN, JM .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1982, 384 (MAY) :394-410
[5]   THERMAL AND CONDUCTIVITY DILUTION CURVES FOR RAPID QUANTITATION OF PULMONARY EDEMA [J].
NOBLE, WH ;
SEVERINGHAUS, JW .
JOURNAL OF APPLIED PHYSIOLOGY, 1972, 32 (06) :770-+
[6]  
PFEIFFER U, 1980, EUR SURG RES, V12, P106
[7]  
PFEIFFER U, 1982, COMPUTERS CRITICAL C, V2, P123
[8]   CONFERENCE REPORT OF A WORKSHOP ON THE MEASUREMENT OF LUNG WATER [J].
STAUB, NC ;
HOGG, JC .
CRITICAL CARE MEDICINE, 1980, 8 (12) :752-759