INTERSUBJECT AND INTRASUBJECT VARIABILITY OF THE THERMODILUTION MEASUREMENT OF RIGHT VENTRICULAR EJECTION FRACTION AND VOLUME IN PATIENTS WITH CHRONIC OBSTRUCTIVE PULMONARY-DISEASE

被引:14
作者
SCHRIJEN, F [1 ]
HENRIQUEZ, A [1 ]
RENONDO, J [1 ]
POINCELOT, F [1 ]
PICHENE, M [1 ]
机构
[1] CHU BRABOIS,F-54500 VANDOEUVRE NANCY,FRANCE
关键词
Cardiac output; Chronic obstructive pulmonary disease; Ejection fraction; Exercise; Thermodilution; Variability;
D O I
10.1093/cvr/24.1.33
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Study objective - To determine the spontaneous changes in volumetric indices of right ventricular function assessed by thermodilution.Design - The study involved measurements of inter- and intraindividual variation of right ventricular function in human subjects at rest and at two different levels of low load supine bicycle exercise.Subjects - The subjects were 23 patients with chronic obstructive pulmonary disease, referred for evaluation by right heart catheterisation. Mean (SEM) age was 55.4 (2.2) years and all were in sinus rhythm.Measurements and results - Successive measurements of ejection fraction and right ventricular end diastolic and end systolic volumes were made by thermodilution with a fast response thermistor mounted in a Swan-Ganz catheter. Five measurements were made at rest (R), and three measurements during each of two levels of exercise (E1, E2). Group average values for each period showed no significant changes with time; interindividual variability was expressed as the coefficient of variation (VC1 = SD/x), intraindividual variability (VC2) as square root of mean value of individual variances. Interindividual variability increased from rest to exercise, while intraindividual variability was lower during exercise, presumably because the variables were more steady. For ejection fraction, VC1, was 23% at rest, 29% for E1, and 32% for E2, while VC2 was 21%, 12% and 15% respectively; for right ventricular end diastolic volume, VC1 was 23% at rest, 29% and 28% during exercise, and VC2 was 17%, 12% and 11% respectively. In some patients cold injection induced bradycardia and spuriously high values of ejection fraction.Conclusions - It is important to monitor heart rate before and during thermodilution measurements and to take into account only those made with stable heart rate. Injectate temperature should be above 10°C.
引用
收藏
页码:33 / 36
页数:4
相关论文
共 8 条
[1]   ASSESSMENT OF CARDIAC-PERFORMANCE WITH QUANTITATIVE RADIONUCLIDE ANGIOCARDIOGRAPHY - RIGHT VENTRICULAR EJECTION FRACTION WITH REFERENCE TO FINDINGS IN CHRONIC OBSTRUCTIVE PULMONARY-DISEASE [J].
BERGER, HJ ;
MATTHAY, RA ;
LOKE, J ;
MARSHALL, RC ;
GOTTSCHALK, A ;
ZARET, BL .
AMERICAN JOURNAL OF CARDIOLOGY, 1978, 41 (05) :897-905
[2]   INFLUENCE OF HEART RATE ON LEFT VENTRICULAR VOLUME IN DOGS [J].
BRISTOW, JD ;
RAPAPORT, E ;
FERGUSON, RE ;
MINTZ, F .
JOURNAL OF CLINICAL INVESTIGATION, 1963, 42 (05) :649-&
[3]  
COLTON T, 1974, STATISTICS MED
[4]  
EATON S, 1988, INTENS CARE MED, V14, P458
[5]   MEASUREMENT OF EJECTION FRACTION BY THERMAL DILUTION TECHNIQUES [J].
KAY, HR ;
AFSHARI, M ;
BARASH, P ;
WEBLER, W ;
ISKANDRIAN, A ;
BEMIS, C ;
HAKKI, AH ;
MUNDTH, ED .
JOURNAL OF SURGICAL RESEARCH, 1983, 34 (04) :337-346
[6]  
PRYSROBERTS C, 1980, CIRCULATION ANAESTHE, P36
[7]  
STETZ CW, 1982, AM REV RESPIR DIS, V126, P1001
[8]  
VOELKER W, 1988, INTENS CARE MED, V14, P461