ACQUISITION AND PROCESSING OF DATA FOR ISOTOPE-RATIO-MONITORING MASS-SPECTROMETRY

被引:150
作者
RICCI, MP [1 ]
MERRITT, DA [1 ]
FREEMAN, KH [1 ]
HAYES, JM [1 ]
机构
[1] INDIANA UNIV,DEPT CHEM,BIOGEOCHEM LABS,BLOOMINGTON,IN 47405
关键词
ISOTOPE-RATIO-MONITORING MASS SPECTROMETRY; ISOTOPIC ANALYSIS; ANALYTICAL PRECISION; ISOTOPE RATIO BACKGROUND LEVELS; CHROMATOGRAPHIC RESOLUTION; ISOTOPE DATA PROCESSING;
D O I
10.1016/0146-6380(94)90002-7
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
Methods are described for continuous monitoring of signals required for precise analyses of C-13, O-18, and N-15 in gas streams containing varying quantities of CO2 and N2. The quantitative resolution (i.e. maximum performance in the absence of random errors) of these methods is adequate for determination of isotope ratios with an uncertainty of one part in 10(5); the precision actually obtained is often better than one part in 10(4). This report describes data-processing operations including definition of beginning and ending points of chromatographic peaks and quantitation of background levels, allowance for effects of chromatographic separation of isotopically substituted species, integration of signals related to specific masses, correction for effects of mass discrimination, recognition of drifts in mass spectrometer performance, and calculation of isotopic delta values. Characteristics of a system allowing off-line revision of parameters used in data reduction are described and an algorithm for identification of background levels in complex chromatograms is outlined. Effects of imperfect chromatographic resolution are demonstrated and discussed and an approach to deconvolution of signals from coeluting substances described.
引用
收藏
页码:561 / 571
页数:11
相关论文
共 25 条
[1]   COMPUTER ANALYSIS OF UNRESOLVED NON-GAUSSIAN GAS CHROMATOGRAMS BY CURVE-FITTING [J].
ANDERSON, AH ;
GIBB, TC ;
LITTLEWOOD, AB .
ANALYTICAL CHEMISTRY, 1970, 42 (04) :434-+
[2]   GAS-CHROMATOGRAPHY - STABLE ISOTOPE RATIO ANALYSIS AT NATURAL ABUNDANCE LEVELS [J].
BARRIE, A ;
BRICOUT, J ;
KOZIET, J .
BIOMEDICAL MASS SPECTROMETRY, 1984, 11 (11) :583-588
[3]  
Bevington P., 1969, DATA REDUCTION ERROR
[5]   GAS CHROMATOGRAPHY OF ISOTOPIC MOLECULES ON OPEN TUBULAR COLUMNS [J].
BRUNER, F ;
CARTONI, GP ;
LIBERTI, A .
ANALYTICAL CHEMISTRY, 1966, 38 (02) :298-&
[6]   AN ISOTOPIC BIOGEOCHEMICAL STUDY OF THE GREEN RIVER OIL-SHALE [J].
COLLISTER, JW ;
SUMMONS, RE ;
LICHTFOUSE, E ;
HAYES, JM .
ORGANIC GEOCHEMISTRY, 1992, 19 (1-3) :265-276
[8]  
FREEDMAN PA, 1988, AM LAB, V20, P114
[9]   EVIDENCE FROM CARBON ISOTOPE MEASUREMENTS FOR DIVERSE ORIGINS OF SEDIMENTARY HYDROCARBONS [J].
FREEMAN, KH ;
HAYES, JM ;
TRENDEL, JM ;
ALBRECHT, P .
NATURE, 1990, 343 (6255) :254-256
[10]   TARGET TRANSFORMATION FACTOR-ANALYSIS WITH LINEAR INEQUALITY CONSTRAINTS APPLIED TO SPECTROSCOPIC CHROMATOGRAPHIC DATA [J].
GEMPERLINE, PJ .
ANALYTICAL CHEMISTRY, 1986, 58 (13) :2656-2663