TOTAL ERYTHROCYTE DESTRUCTION TIME - THE NEW INDEX FOR THE HEMOLYTIC PERFORMANCE OF ROTARY BLOOD PUMPS

被引:22
作者
SHIMONO, T
MAKINOUCHI, K
NOSE, Y
机构
[1] Department of Surgery, Baylor College of Medicine, Houston, Texas
关键词
CENTRIFUGAL PUMP; HEMOLYSIS; BLOOD TRAUMA; IN VITRO TEST; ERYTHROCYTE;
D O I
10.1111/j.1525-1594.1995.tb02383.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
To date an index of hemolysis is the only parameter to evaluate in vitro the hemolytic properties of blood pumps, However, this index does not reflect the sublethal conditions of erythrocytes. In this paper, a new concept, the total destruction of erythrocytes, to indicate traumatic features on erythrocytes is proposed. Five paired long duration in vitro hemolysis tests were conducted using the BioMedicus pump; BP80, and the Nikkiso pump, HMS12. The pumps ran until either a sudden change in blood color to dark red was noted or the pumps ran for over 24 h. At a certain point, the plasma-free hemoglobin levels suddenly and dramatically increased in each experiment except one Nikkiso case. At a certain point in time, the destruction of most erythrocytes suddenly and simultaneously occurred. We call this phenomenon total destruction of erythrocytes and define the pumping duration required to raise the level of the plasma-free hemoglobin to 50% of the total hemoglobin as total destruction time. Although there is no statistical difference in the normalized index of hemolysis between the two pumps, the total destruction time of the BioMedicus pump is significantly shorter than that of the Nikkiso pump. It appears that an accumulation of sublethal damage on erythrocytes resulted in the decrease of the hemolytic threshold of the entire erythrocyte and also resulted in a sudden entire destruction of erythrocytes.
引用
收藏
页码:571 / 575
页数:5
相关论文
共 8 条
[1]  
Extracorporeal circulation, (1960)
[2]  
Standefer JC, Vanderjagt D., Use of tetramethylbenzidine in plasma hemoglobin assay, Clin Chem, 23, pp. 749-751, (1977)
[3]  
Koller T, Hawrylenko A., Contribution to the in vitro testing of pumps for extracorporeal circulation, J Thorac Cardio-vasc Surg, 54, pp. 22-29, (1967)
[4]  
Del Guercio LRM, Savino JA., Physiologic monitoring of the surgical patient, Principles of surgery, (1989)
[5]  
Mueller MR, Schima H, Engelhard H, Salat A, Olsen DB, Losert U, Wolner E., In vitro hematological testing of rotary blood pump: Remarks on standardization and data interpretation, Artif Organs, 17, pp. 103-110, (1993)
[6]  
Oku T, Harasaki H, Smith W, Nose Y., Hemolysis: A comparative study of four nonpulsatile pumps, Trans Am Soc Artif Intern Organs, 34, pp. 500-504, (1988)
[7]  
Jakob H, Kutschera Y, Palzer B, Prellwitz W, Oelert H., In‐vitro assessment of centrifugal pumps for ventricular assist, Artif Organs, 14, pp. 278-283, (1990)
[8]  
Orime Y, Takatani S, Sask T, Aiwa T, Ohara Y, Naito K, Glueck J, Noon GP, Nose Y, DeBakey ME., Cardiopulmo‐nary bypass with Nikkiso and BioMedicus centrifugal pumps, Artif Organs, 18, pp. 11-16, (1994)