PREPARATION AND STORAGE IN PLASMA-LYTE-A OF PLATELETS COLLECTED WITH THE CELL SEPARATOR CS3000-PLUS EQUIPPED WITH THE PLT30-SEPARATION AND TNX6 COLLECTION CHAMBERS

被引:14
作者
VALBONESI, M
FLORIO, G
FRISONI, R
MORELLI, F
机构
[1] Divisione di Immunoematologia, Ospedale S. Martino
关键词
PLATELETPHERESIS; THROMBOCYTAPHERESIS; PLATELET TRANSFUSION; PLATELET STORAGE; PLATELET FUNCTION; PLATELET GLYCOPROTEINS; PLATELET MEMBRANE;
D O I
10.1177/039139889501800109
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The last five years have been characterized by the presentation of new cell separators the main task of which is the collection of high yield-high qualify platelets. The CS3000 is an old apparatus which has undergone rejuvenation to sustain the assault of its new competitors. The CS3000 Plus Omnix system is the latest version to be offered along wth a combination of TNX-6 separation/PLT30 collection chambers for optimal platelet collection. In this paper we present our results with this apparatus and configuration after its adaptation to the collection and storage of platelets in a non-plasma medium, the Baxter Plasma-Lyte A. After separation the platelet product (PC) was left in the collection chamber and resuspended with 200 ml of Plasma-Lyte A instead of being resuspended in autologous plasma as usual. Plasma was collected in a separate bag (400-450 ml) for transfusion or fractionation purposes. PC qualify was assessed by evaluating the platelet yield (4.17 +/- 1.8 x 10(11)), and the WBC contamination (4.8 +/- 2.6 x 10(5)). The presence of platelet aggregates (platelet count after aggregate fixation with formalin/platelet count after disaggregation in EDTA), the aggregation induced by ADP, collagen and ristocetin, the hypotonic shock response and the stability of membrane glycoproteins (CD 62 - 63 - 36 - 42b - 51) were measured in the preapheresis samples and in the PC immediately after, 24 and 72 hours after collection. These results were totally satisfactory as was the post-transfusion survival measured as corrected count increment in 10 transfusions to non refractory patients. If is concluded that the preparation and storage in Plasma-Lyte A of platelets collected with the CS3000 Plus-Omnix apparatus with the TNX6-PLT30 configuration is not only feasible but advisable.
引用
收藏
页码:39 / 44
页数:6
相关论文
共 19 条
[1]  
ADAMS GA, 1986, BLOOD, V67, P672
[2]   HEMAPHERESIS LISTENING POST - THE GROWING PRACTICE OF SPLITTING DOUBLE-DOSE APHERESIS PLATELET PRODUCTS [J].
AXELROD, FB .
TRANSFUSION SCIENCE, 1993, 14 (04) :364-368
[3]  
BLAJCHMAN MA, 1992, BLOOD, V79, P1371
[4]   ULTRAVIOLET-IRRADIATION OF PLATELET CONCENTRATES - INVITRO AND INVIVO PRECLINICAL EVALUATION [J].
BOCCACCIO, C ;
GARCIA, I ;
KLAREN, J ;
BAUDARD, M ;
LECRUBIER, C ;
FOURNEL, JJ ;
SAMAMA, M ;
ANDREU, G .
TRANSFUSION SCIENCE, 1990, 11 (02) :141-147
[5]   EXPERIMENTAL ANIMAL-MODEL OF REFRACTORINESS TO DONOR PLATELETS - THE EFFECT OF PLASMA REMOVAL AND THE EXTENT OF WHITE CELL-REDUCTION ON ALLOGENEIC ALLOIMMUNIZATION [J].
BORDIN, JO ;
BARDOSSY, L ;
BLAJCHMAN, MA .
TRANSFUSION, 1993, 33 (10) :798-801
[6]   DETECTION OF PLATELET ACTIVATION WITH MONOCLONAL-ANTIBODIES AND FLOW-CYTOMETRY - CHANGES DURING PLATELET STORAGE [J].
FIJNHEER, R ;
MODDERMAN, PW ;
VELDMAN, H ;
OUWEHAND, WH ;
NIEUWENHUIS, HK ;
ROOS, D ;
DEKORTE, D .
TRANSFUSION, 1990, 30 (01) :20-25
[7]   PREVALENCE OF PLATELET TRANSFUSION REACTIONS BEFORE AND AFTER IMPLEMENTATION OF LEUKOCYTE-DEPLETED PLATELET CONCENTRATES BY FILTRATION [J].
GOODNOUGH, LT ;
RIDDELL, J ;
LAZARUS, H ;
CHAFEL, TL ;
PRINCE, G ;
HENDRIX, D ;
YOMTOVIAN, R .
VOX SANGUINIS, 1993, 65 (02) :103-107
[8]  
HOURDILLE P, 1990, BLOOD, V76, P1503
[9]  
KAO KJ, 1992, BLOOD, V80, P2931
[10]   PLATELET RESPONSE TO HYPOTONIC SHOCK - ITS VALUE AS AN INDICATOR OF PLATELET VIABILITY AFTER STORAGE [J].
KIM, BK ;
BALDINI, MG .
TRANSFUSION, 1974, 14 (02) :130-138