IN-VITRO ASSESSMENT OF WATER-VAPOR TRANSMISSION OF SYNTHETIC WOUND DRESSINGS

被引:196
作者
WU, P [1 ]
FISHER, AC [1 ]
FOO, PP [1 ]
QUEEN, D [1 ]
GAYLOR, JDS [1 ]
机构
[1] CONVATEC LTD, WOUND HEALING RES INST, DEESIDE CH5 2NU, CLWYD, WALES
关键词
WOUND DRESSINGS; HYDROCOLLOID; WATER VAPOR TRANSMISSION; AIR VELOCITY;
D O I
10.1016/0142-9612(95)92114-L
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The water vapour transmission rate (WVTR) of 14 commercially available synthetic wound dressings (11 hydrocolloids, 2 hydrogels and 1 polyurethane film) was evaluated over 24 and 48 h periods using a modified ASTM standard method (ASTM E96-90). For the 48 h studies a novel microcomputer-controlled apparatus was employed. The dressings exhibited a wide range of WVTRs (76-9360 g m(-2) d(-1) at 24 h under forced air convection of 0.4 m s(-1)). The influence of air velocity of 0.4 m s(-1) was not significant if the WVTR of the dressing was less than 880 g m(-2) d(-1) when measured under static air conditions. The influence of outer barrier layers and additional bandages on WVTR was also examined.
引用
收藏
页码:171 / 175
页数:5
相关论文
共 12 条
[1]  
BOLTON L, 1990, CLIN RES PRACTICE, V2, P126
[2]   SYNTHETIC HYDROGELS .6. HYDROGEL COMPOSITES AS WOUND DRESSINGS AND IMPLANT MATERIALS [J].
CORKHILL, PH ;
HAMILTON, CJ ;
TIGHE, BJ .
BIOMATERIALS, 1989, 10 (01) :3-10
[3]  
Eaglstein W H, 1984, Clin Dermatol, V2, P107, DOI 10.1016/0738-081X(84)90032-4
[4]  
FOO PP, 1987, THESIS STRATHCLYDE U
[5]  
HINMAN CD, 1963, NATURE, V200, P377, DOI [10.1038/200377a0, 10.1038/200378a0]
[6]   OCCLUSIVE DRESSINGS - A MICROBIOLOGIC AND CLINICAL REVIEW [J].
HUTCHINSON, JJ ;
MCGUCKIN, M .
AMERICAN JOURNAL OF INFECTION CONTROL, 1990, 18 (04) :257-268
[7]   NEW METHOD TO ASSESS THE WATER-VAPOR PERMEANCE OF WOUND COVERINGS [J].
JONKMAN, MF ;
MOLENAAR, I ;
NIEUWENHUIS, P ;
BRUIN, P ;
PENNINGS, AJ .
BIOMATERIALS, 1988, 9 (03) :263-267
[8]   EVAPORATIVE WATER-LOSS FROM BURNS AND WATER-VAPOR PERMEABILITY OF GRAFTS AND ARTIFICIAL MEMBRANES USED IN TREATMENT OF BURNS [J].
LAMKE, LO ;
NILSSON, GE ;
REITHNER, HL .
BURNS, 1977, 3 (03) :159-165
[9]  
LELAH MD, 1986, POLYURETHANES MED, P57
[10]   THE PRECLINICAL EVALUATION OF THE WATER-VAPOR TRANSMISSION RATE THROUGH BURN WOUND DRESSINGS [J].
QUEEN, D ;
GAYLOR, JDS ;
EVANS, JH ;
COURTNEY, JM ;
REID, WH .
BIOMATERIALS, 1987, 8 (05) :367-371