CONVENTIONAL 15G NEEDLE TECHNIQUE FOR RENAL BIOPSY COMPARED WITH ULTRASOUND-GUIDED SPRING-LOADED 18G NEEDLE-BIOPSY

被引:66
作者
COZENS, NJA
MURCHISON, JT
ALLAN, PL
WINNEY, RJ
机构
[1] ROYAL INFIRM,DEPT RADIOL,EDINBURGH EH3 9HB,MIDLOTHIAN,SCOTLAND
[2] ROYAL INFIRM,DEPT RENAL MED,EDINBURGH EH3 9HB,MIDLOTHIAN,SCOTLAND
关键词
NEEDLE BIOPSY; KIDNEY; ULTRASOUND;
D O I
10.1259/0007-1285-65-775-594
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Two techniques for percutaneous renal biopsy were retrospectively reviewed to assess their relative safety and efficacy. Ultrasound localization of the kidney by a radiologists, with subsequent biopsy performed by a renal physician using a hand-held 15 G cutting needle (Tru-Cut), was compared with biopsy performed by a radiologist using an 18 G cutting needle with a spring-loaded biopsy device (Biopty) and real-time ultrasound guidance. The smaller needle with real-time ultrasound is more reliable at retrieving an adequate specimen for histological examination (93%) than the "conventional" technique (79%). Fewer complications occurred in the Biopty group although the difference did not reach statistical significance. The average length of stay in hospital was significantly shorter for elective biopsies with the Biopty device (1.80 compared with 2.93 nights, p < 0.01). We recommend the use of the Biopty device with an 18 G needle and real-time ultrasound guidance as the method of choice for percutaneous renal biopsy.
引用
收藏
页码:594 / 597
页数:4
相关论文
共 11 条
[1]  
Ball DP, 1934, J TENNESSEE MED ASS, V27, P203
[2]  
BEAMAN M, 1989, BRIT J HOSP MED, V41, P158
[3]   NEEDLE-BIOPSY OF RENAL-ALLOGRAFTS - COMPARISON OF 2 TECHNIQUES [J].
BOGAN, ML ;
KOPECKY, KK ;
KRAFT, JL ;
HOLLADAY, AO ;
FILO, RS ;
LEAPMAN, SB ;
THOMALLA, JV .
RADIOLOGY, 1990, 174 (01) :273-275
[4]   THE IMPORTANCE OF SAMPLE-SIZE IN THE INTERPRETATION OF THE RENAL BIOPSY [J].
CORWIN, HL ;
SCHWARTZ, MM ;
LEWIS, EJ .
AMERICAN JOURNAL OF NEPHROLOGY, 1988, 8 (02) :85-89
[5]  
KARK RM, 1954, LANCET, V1, P1047
[6]   PERCUTANEOUS NEEDLE-BIOPSY - A NEW TECHNIQUE [J].
LINDGREN, PG .
ACTA RADIOLOGICA-DIAGNOSIS, 1982, 23 (06) :653-656
[7]   RENAL BIOPSY [J].
MADAIO, MP .
KIDNEY INTERNATIONAL, 1990, 38 (03) :529-543
[8]  
MORRISON RT, 1990, KIDNEY INT, V37, P281
[9]  
Murphy B F, 1989, Am J Kidney Dis, V14, P77
[10]   IMAGE-DIRECTED PERCUTANEOUS BIOPSIES WITH A BIOPSY GUN [J].
PARKER, SH ;
HOPPER, KD ;
YAKES, WF ;
GIBSON, MD ;
OWNBEY, JL ;
CARTER, TE .