XENON-COMPUTED TOMOGRAPHY CEREBRAL BLOOD-FLOW MEASUREMENTS - METHODS AND ACCURACY

被引:42
作者
FATOUROS, PP
WIST, AO
KISHORE, PRS
DEWITT, DS
HALL, JA
KEENAN, RL
STEWART, LM
MARMAROU, A
CHOI, SC
KONTOS, HA
机构
[1] VIRGINIA COMMONWEALTH UNIV,MED COLL VIRGINIA,DEPT SURG,RICHMOND,VA 23298
[2] VIRGINIA COMMONWEALTH UNIV,MED COLL VIRGINIA,DEPT ANESTHESIOL,RICHMOND,VA 23298
[3] VIRGINIA COMMONWEALTH UNIV,MED COLL VIRGINIA,DEPT MED,RICHMOND,VA 23298
[4] VIRGINIA COMMONWEALTH UNIV,MED COLL VIRGINIA,DEPT BIOSTAT,RICHMOND,VA 23298
关键词
D O I
10.1097/00004424-198709000-00003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
引用
收藏
页码:705 / 712
页数:8
相关论文
共 18 条
[1]   SOME SOURCES OF ERROR IN MEASURING REGIONAL BLOOD FLOW WITH RADIOACTIVE MICROSPHERES [J].
BUCKBERG, GD ;
LUCK, JC ;
PAYNE, DB ;
HOFFMAN, JIE ;
ARCHIE, JP ;
FIXLER, DE .
JOURNAL OF APPLIED PHYSIOLOGY, 1971, 31 (04) :598-&
[2]  
DEWITT DS, 1987, J CEREBR BLOOD FL S1, V7, P574
[3]  
DHAWAN V, 1984, J COMPUT ASSIST TOMO, V8, P208
[4]   XENON ENHANCED CT FOR ANALYSIS OF CEREBRAL INTEGRITY, PERFUSION, AND BLOOD-FLOW [J].
DRAYER, BP ;
WOLFSON, SK ;
REINMUTH, OM ;
DUJOVNY, M ;
BOEHNKE, M ;
COOK, EE .
STROKE, 1978, 9 (02) :123-130
[5]   INVIVO MAPPING OF LOCAL CEREBRAL BLOOD-FLOW BY XENON-ENHANCED COMPUTED-TOMOGRAPHY [J].
GUR, D ;
GOOD, WF ;
WOLFSON, SK ;
YONAS, H ;
SHABASON, L .
SCIENCE, 1982, 215 (4537) :1267-1268
[6]   SIMULTANEOUS MEASUREMENTS OF CEREBRAL BLOOD-FLOW BY THE XENON CT METHOD AND THE MICROSPHERE METHOD - A COMPARISON [J].
GUR, D ;
YONAS, H ;
JACKSON, DL ;
WOLFSON, SK ;
ROCKETTE, H ;
GOOD, WF ;
COOK, EE ;
ARENA, VC ;
WILLY, JA ;
MAITZ, GS .
INVESTIGATIVE RADIOLOGY, 1985, 20 (07) :672-677
[7]   REGIONAL DISTRIBUTION OF BLOOD-FLOW IN AWAKE HEAT-STRESSED BABOONS [J].
HALES, JRS ;
ROWELL, LB ;
KING, RB .
AMERICAN JOURNAL OF PHYSIOLOGY, 1979, 237 (06) :H705-H712
[8]   VALIDITY STUDIES OF RADIOACTIVE MICROSPHERE METHOD FOR STUDY OF DISTRIBUTION OF CARDIAC OUTPUT, ORGAN BLOOD FLOW, AND RESISTANCE IN CONSCIOUS RHESUS MONKEY [J].
HOFFBRAND, BI ;
FORSYTH, RP .
CARDIOVASCULAR RESEARCH, 1969, 3 (04) :426-+
[9]   COMPUTED TOMOGRAPHIC MEASUREMENT OF XENON BRAIN-BLOOD PARTITION-COEFFICIENT AND IMPLICATIONS FOR REGIONAL CEREBRAL BLOOD-FLOW - PRELIMINARY-REPORT [J].
KELCZ, F ;
HILAL, SK ;
HARTWELL, P ;
JOSEPH, PM .
RADIOLOGY, 1978, 127 (02) :385-392
[10]   REGIONAL CEREBRAL BLOOD-FLOW MEASUREMENTS USING STABLE XENON ENHANCED COMPUTED-TOMOGRAPHY - A THEORETICAL AND EXPERIMENTAL EVALUATION [J].
KISHORE, PRS ;
RAO, GU ;
FERNANDEZ, RE ;
KEENAN, RL ;
ARORA, GD ;
GADISSEUX, P ;
STEWART, LM ;
WIST, AO ;
FATOUROS, PP ;
DILLARD, D ;
WATSON, CK .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1984, 8 (04) :619-630