QUANTITATIVE SPECT IMAGING WITH IN-111

被引:14
作者
GILLAND, DR
JASZCZAK, RJ
TURKINGTON, TG
GREER, KL
COLEMAN, RE
机构
[1] Department of Radiology, Duke University Medical Center, United States
关键词
D O I
10.1109/23.289386
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The potential of SPECT to quantify the distribution of indium-111 was investigated in an experimental phantom study. Non-uniform attenuation compensation using acquired transmission data was compared to uniform compensation based on reconstructed quantitative accuracy and noise. The reconstructed transmission data provided the attenuation map for the non-uniform compensation. Results showed that non-uniform attenuation compensation improved image quality, quantitative accuracy, and noise compared to uniform compensation. Noise increased with a decrease in counts in the non-uniform attenuation map but remained substantially below the uniform compensation level. The noise effect was observed with both Chang and ML-EM reconstruction methods. Independent reconstruction of the 172 and 247 keV emission data was compared to the reconstruction of the combined 172 and 247 keV projection data. Improved quantitative accuracy and image noise resulted when both In-111 emission energies were used. However, independent reconstruction of the two energies did not substantially improve accuracy or noise compared with the reconstruction of the combined data.
引用
收藏
页码:761 / 766
页数:6
相关论文
共 21 条
[1]  
BAILEY DL, 1987, J NUCL MED, V28, P844
[2]   3-DIMENSIONAL RECONSTRUCTION IN NUCLEAR-MEDICINE EMISSION IMAGING [J].
BUDINGER, TF ;
GULLBERG, GT .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1974, NS21 (03) :2-20
[4]  
GILLAND DR, IN PRESS J NUCL MED
[5]   AN ATTENUATED PROJECTOR BACKPROJECTOR FOR ITERATIVE SPECT RECONSTRUCTION [J].
GULLBERG, GT ;
HUESMAN, RH ;
MALKO, JA ;
PELC, NJ ;
BUDINGER, TF .
PHYSICS IN MEDICINE AND BIOLOGY, 1985, 30 (08) :799-816
[6]   SCINTIGRAPHY WITH IN-111-LABELED MONOCLONAL ANTITUMOR ANTIBODIES - KINETICS, BIODISTRIBUTION, AND TUMOR-DETECTION [J].
HALPERN, SE ;
HAINDL, W ;
BEAUREGARD, J ;
HAGAN, P ;
CLUTTER, M ;
AMOX, D ;
MERCHANT, B ;
UNGER, M ;
MONGOVI, C ;
BARTHOLOMEW, R ;
JUE, R ;
CARLO, D ;
DILLMAN, R .
RADIOLOGY, 1988, 168 (02) :529-536
[7]  
JASZCZAK RJ, 1977, J NUCL MED, V18, P373
[8]  
JASZCZAK RJ, 1984, J NUCL MED, V25, P893
[9]  
KING MA, 1986, J NUCL MED, V27, P1327
[10]  
LANGE K, 1984, J COMPUT ASSIST TOMO, V8, P306