ANALYSIS OF COMBUSTION PRODUCTS USING TIME-OF-FLIGHT MASS-SPECTROMETRY

被引:12
作者
LOEPFE, M
BURTSCHER, H
SIEGMANN, HC
机构
[1] Laboratory for Solid State Physics, ETH-Hönggerberg, Zürich
关键词
D O I
10.1007/BF00479401
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Time of flight mass spectrometry (TOF-MS) combined with resonant two-photon ionization is applied to detect aromatic hydrocarbons in combustion products. The sample is introduced through a heated capillary into the supersonic jct of a TOF-MS. For ionization, a tunable, frequency-doubled dye-laser is used. The inlet system-allows a direct measurement of samples at atmospheric pressure. The resonant ionization can distinguish structural isomers without preceding chromatography. The short response time of the system allows for example on-line monitoring of combustion emissions. This is demonstrated by thermo-desorption experiments of anthracene from activated charcoal and from diesel soot. A significant higher desorption temperature from charcoal than from diesel soot is found. In addition, examples showing selective measurements of benzene, toluene and three dimethyl-benzene isomers in the exhaust gas of a gasoline engine are presented.
引用
收藏
页码:177 / 184
页数:8
相关论文
共 4 条
[1]  
GRIMMER G, 1983, POLYNUCLEAR AROMATIC, P571
[2]  
NAKHIMOVSKY LA, 1989, HDB TEMPERATURE LOW
[3]  
RIVIN D, 1983, SOOT COMBUSTION SYST, P26
[4]  
SIOMOS K, 1989, CHEM ANAL POLYCYCLIC, P263