CEPHALOMETRIC ERRORS - A COMPARISON BETWEEN REPEAT MEASUREMENTS AND RETAKEN RADIOGRAPHS

被引:36
作者
COOKE, MS
WEI, SHY
机构
[1] Department of Children's Dentistry and Orthodontics, University of Hong Kong
[2] Department of Children's Dentistry and Orthodontics, University of Hong Kong
关键词
CEPHALOMETRIC ERRORS; LATERAL CEPHALOMETRIC RADIOGRAPHY; REPRODUCIBILITY;
D O I
10.1111/j.1834-7819.1991.tb00806.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study compares landmark location errors in cephalometric radiography (when re-measuring radiographs) and radiographic errors (when retaking the radiograph). The samples comprised 32 re-measured and re-digitized radiographs and a further series of 22 retaken radiographs drawn from the same overall sample of 12-year-old Chinese children in Hong Kong. All radiographs were recorded in natural head posture with the lips in light contact. The relative size of the errors were assessed by calculating the 'error percentage' for both selected dento-skeletal and soft tissue profile measures. It is suggested that this index is clinically more meaningful than the usually used 'method error'. It expresses the variance of the method error (me2) as a percentage of the variance of the measurement under study (standard deviation2). This error percentage was found to be doubled, on average, for measurements on the retaken radiographs. In general, measures with most landmarks in the mid-sagittal plane showed the least increase in percentage error. The results suggest that errors arising from retaking cephalometric radiographs may effectively be greater than those usually reported. The Frankfort plane, the functional occlusal plane and the incisor long axes displayed poor reproducibility. For the soft tissues the tips served as poor angular landmarks and relatively acute angles with short 'arms' also displayed large errors.
引用
收藏
页码:38 / 43
页数:6
相关论文
共 23 条
[1]  
Bjork A., The face in profile, Sven Tandlak Tidskr, 40, pp. 30-50, (1947)
[2]  
Hatton ME, Grainger RM., Reliability of measurements from cephalograms at the Burlington Orthodontic Research Centre, J Dent Res, 37, pp. 853-859, (1958)
[3]  
Midtgard J., Bjork G., Linder-Aronson S., Reproducibility of cephalometric landmarks and errors of measurements of cephalometric cranial distances, Angle Orthod, 44, pp. 56-61, (1974)
[4]  
Sandler PJ., (1986)
[5]  
Sandler PJ., Effect of patient repositioning on cephalometric measurements, Br J Orthod, 15, pp. 17-21, (1988)
[6]  
Mills JRE., Principles and practice of orthodontics, pp. 74-75, (1982)
[7]  
Ahlqvist J., Eliasson S., Welander U., The effects of projection errors on cephalometric length measurements, Eur J Orthod, 8, pp. 141-148, (1986)
[8]  
Houston WJB, Maher RE, McElroy D., Sherriff M., Sources of error in measurements from cephalometric radiographs, Eur J Orthod, 8, pp. 149-151, (1986)
[9]  
Buschang PH, Tanguay R., Demirjian A., Cephalometric reliability. A full ANOVA model for the estimation of true and error variance, Angle Orthod, 57, pp. 168-175, (1987)
[10]  
Hillesund E., Ejeld D., Sherriff M., Sources of error in measurements from cephalometric radiographs, Eur J Orthod, 8, pp. 149-151, (1986)