BREAST-CANCER DIAGNOSIS AND PROGNOSIS IN WOMEN FOLLOWING AUGMENTATION WITH SILICONE GEL-FILLED PROSTHESES

被引:60
作者
SILVERSTEIN, MJ
HANDEL, N
GAMAGAMI, P
GIERSON, ED
FURMANSKI, M
COLLINS, AR
EPSTEIN, M
COHLAN, BF
机构
关键词
D O I
10.1016/S0959-8049(05)80115-7
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
62 healthy women were studied mammographically before and after augmentation mammoplasty. Postaugmentation mammograms were done using both the implant compression and implant displacement technique. The amount of visualisable tissue was measured in all films before and after augmentation. We concluded: State-of-the-art film-screen mammography is extremely difficult to obtain in most patients augmented with silicone-gel-filled prostheses. On average, there is a decrease in measurable visualised breast tissue after augmentation mammoplasty with silicone-gel-filled prostheses. The area of mammographically measurable tissue is no different whether smooth or textured implants are used. Textured implants are less likely to form an early capsular contracture and are therefore preferred. However, the cancer-causing potential of polyurethane in humans is currently unknown. Anterior breast tissue is generally seen better with displacement mammography; posterior breast tissue with compression mammography. Better films are generally obtained when the implant is in the subpectoral position rather than subglandular. The more severe the capsular contracture, the poorer the mammogram. In addition 42 previously augmented patients developed breast carcinomas an average of 8.4 years after augmentation with silicone-gel-filled impants; 95% had palpable lesions (only 60% of which could be seen on mammography), 90% had infiltrating carcinomas, 45% had metastases to axillary nodes, and 7 patients have recurred, 5 of whom have died. We concluded: Augmented women who develop breast cancer are similar, in terms of tumour size and nodal positivity, to non-augmented breast cancer patients who present with palpable masses. When compared with non-augmented women whose breast cancers are found with screening mammography, augmented patients with breast cancer present with a higher percentage of invasive lesions and involved axillary lymph nodes, resulting in a poorer prognosis. The 40% false negative rate for mammography in this series is unduly high and alarming. Augmentation mammoplasty with silicone-gel-filled implants should be discouraged in women with a high risk of developing breast cancer.
引用
收藏
页码:635 / 640
页数:6
相关论文
共 31 条
[1]  
AMALRIC R, 1982, CANCER-AM CANCER SOC, V49, P30, DOI 10.1002/1097-0142(19820101)49:1<30::AID-CNCR2820490107>3.0.CO
[2]  
2-L
[3]  
BEDWANI R, 1981, CANCER, V47, P2769, DOI 10.1002/1097-0142(19810615)47:12<2769::AID-CNCR2820471202>3.0.CO
[4]  
2-7
[5]  
BRODY GS, 1989, PLAST RECONSTR SURG, V84, P779
[6]  
BRODY GS, 1989, ARCH SURG-CHICAGO, V124, P257
[7]  
CARDY RH, 1979, J NATL CANCER I, V62, P1107
[8]   THE RELATIONSHIP BETWEEN BREAST-CANCER AND AUGMENTATION MAMMAPLASTY - AN EPIDEMIOLOGIC-STUDY [J].
DEAPEN, DM ;
PIKE, MC ;
CASAGRANDE, JT ;
BRODY, GS .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1986, 77 (03) :361-367
[9]   IMPROVED IMAGING OF THE AUGMENTED BREAST [J].
EKLUND, GW ;
BUSBY, RC ;
MILLER, SH ;
JOB, JS .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 151 (03) :469-473
[10]   RATE AND INCIDENCE OF CAPSULAR CONTRACTURE - A COMPARISON OF SMOOTH AND TEXTURED SILICONE DOUBLE-LUMEN BREAST PROSTHESES [J].
ERSEK, RA .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1991, 87 (05) :879-884