THE DEVELOPMENT OF A MICROWAVE FLUID-BED PROCESSOR .2. DRYING PERFORMANCE AND PHYSICAL CHARACTERISTICS OF TYPICAL PHARMACEUTICAL GRANULATIONS

被引:12
作者
DOELLING, MK [1 ]
NASH, RA [1 ]
机构
[1] ST JOHNS UNIV,COLL PHARM & ALLIED HLTH PROFESS,JAMAICA,NY 11439
关键词
MICROWAVE DRYER; FLUID-BED DRYER; PROCESS EQUIPMENT VALIDATION;
D O I
10.1023/A:1015827416892
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Four typical pharmaceutical granulations were used to measure the enhanced drying performance of a laboratory-sized microwave fluid-bed processor, the design and construction of which were presented in Part I of this work (preceding paper). Results demonstrate improvements in observed drying rates by as much as sixfold depending upon the granulation type and drying conditions. At a low inlet temperature (30-degrees-C), drying was achieved with microwave power inputs of 100-125 W/liter of working capacity, whereas similar targeted moisture levels were unattainable using conventional fluid-bed drying. Microwave energy available for heating and drying was 68 to 86% of the total microwave energy inputted.
引用
收藏
页码:1493 / 1501
页数:9
相关论文
共 7 条
[1]  
CALLAHAN JC, 1982, DRUG DEV IND PHARM, P355
[2]   TRAY DRYING OF PHARMACEUTICAL WET GRANULATIONS [J].
CARSTENSEN, JT ;
ZOGLIO, MA .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1982, 71 (01) :35-39
[3]  
DOELLING MK, 1992, PHARM RES, V9
[4]  
DOYLE C, 1987, MANUF CHEMIST, V32, P23
[5]  
LACHMAN L, 1976, THEORY PRACTICE IND, P482
[6]  
SMITH F, 1988, RES DEV JAN