COLOR-FLOW DUPLEX SCANNING OF CAROTID ARTERIES - NEW VELOCITY CRITERIA-BASED ON RECEIVER OPERATOR CHARACTERISTIC ANALYSIS FOR THRESHOLD STENOSES USED IN THE SYMPTOMATIC AND ASYMPTOMATIC CAROTID TRIALS

被引:147
作者
FAUGHT, WE [1 ]
MATTOS, MA [1 ]
VANBEMMELEN, PS [1 ]
HODGSON, KJ [1 ]
BARKMEIER, LD [1 ]
RAMSEY, DE [1 ]
SUMNER, DS [1 ]
机构
[1] SO ILLINOIS UNIV, SCH MED, DEPT SURG, PERIPHERAL VASC SURG, SPRINGFIELD, IL 62794 USA
关键词
D O I
10.1016/S0741-5214(94)70006-0
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: Duplex scanning has become the standard for noninvasive evaluation of carotid arteries. However, current ultrasound criteria for internal carotid artery (ICA) stenosis (16% to 49%, 50% to 79%, 80% to 99%) may not be applicable to the categories (30% to 49%, 50% to 69%, 70% to 99%) used in ongoing symptomatic and asymptomatic carotid endarterectomy trials. This study was undertaken to determine new velocity criteria consistent with these categories. Methods: From January 1, 1989 through October 30, 1992, 5871 color-flow duplex scans were obtained in our laboratories. After inadequate arteriograms and patients with a contralateral ICA occlusion were excluded, 770 peak systolic velocity (PSV) and 229 end-diastolic velocity (EDV) measurements were available for comparison with arteriography. ICA PSV and EDV were subjected to receiver operator characteristic curve analysis to determine optimum criteria for identifying stenoses of 30%, 50%, and 70%. Results: For 70% to 99% carotid artery stenosis, PSV greater than 130 plus EDV greater than 100 provided the best sensitivity (81%), specificity (98%), positive predictive value (89%), negative predictive value (96%), and overall accuracy (95%). For 50% to 69% stenosis, a PSV greater than 130 and EDV of 100 or less cm/sec proved to be the best combination: sensitivity (92%), specificity (97%), positive predictive value (93%), negative predictive value (99%), and accuracy (97%). Stenoses in the 30% to 49% range were less accurately identified. Conclusion: These redefined criteria may prove useful for analyzing duplex ultrasound velocity data in reference to the classification of ICA stenosis used in recent clinical trials of the safety and efficacy of carotid endarterectomy.
引用
收藏
页码:818 / 828
页数:11
相关论文
共 20 条
[1]
CAROTID ENDARTERECTOMY AND THE MEASUREMENT OF STENOSIS [J].
BARNETT, HJM ;
WARLOW, CP .
STROKE, 1993, 24 (09) :1281-1284
[2]
OBSERVER VARIABILITY IN EVALUATING EXTRA-CRANIAL CAROTID-ARTERY STENOSIS [J].
CHIKOS, PM ;
FISHER, LD ;
HIRSCH, JH ;
HARLEY, JD ;
THIELE, BL ;
STRANDNESS, DE .
STROKE, 1983, 14 (06) :885-892
[3]
[4]
Daigle RJ, 1990, J VASC TECHNOL, V14, P206
[5]
IS DUPLEX SCANNING SUFFICIENT EVALUATION BEFORE CAROTID ENDARTERECTOMY [J].
GEUDER, JW ;
LAMPARELLO, PJ ;
RILES, TS ;
GIANGOLA, G ;
IMPARATO, AM .
JOURNAL OF VASCULAR SURGERY, 1989, 9 (02) :193-201
[6]
HOBSON RW, 1986, STROKE, V17, P534
[7]
LONDREY GL, 1991, J VASC SURG, V13, P659
[8]
MARSHALL WG, 1988, CIRCULATION, V78, P1
[9]
IDENTIFYING TOTAL CAROTID OCCLUSION WITH COLOR FLOW DUPLEX SCANNING [J].
MATTOS, MA ;
HODGSON, KJ ;
RAMSEY, DE ;
BARKMEIER, LD ;
SUMNER, DS .
EUROPEAN JOURNAL OF VASCULAR SURGERY, 1992, 6 (02) :204-210
[10]
CORRELATION OF NORTH-AMERICAN SYMPTOMATIC CAROTID ENDARTERECTOMY TRIAL (NASCET) ANGIOGRAPHIC DEFINITION OF 70-PERCENT TO 99-PERCENT INTERNAL CAROTID-ARTERY STENOSIS WITH DUPLEX SCANNING [J].
MONETA, GL ;
EDWARDS, JM ;
CHITWOOD, RW ;
TAYLOR, LM ;
LEE, RW ;
CUMMINGS, CA ;
PORTER, JM ;
THIELE, B ;
HOBSON, R ;
RICOTTA, J ;
HUNINK, M ;
CUNHA, SS ;
BARNES, R .
JOURNAL OF VASCULAR SURGERY, 1993, 17 (01) :152-159