QUANTITATIVE ASSESSMENT OF IMPEDANCE TOMOGRAPHY FOR TEMPERATURE-MEASUREMENTS IN HYPERTHERMIA

被引:20
作者
BLAD, B [1 ]
PERSSON, B [1 ]
LINDSTROM, K [1 ]
机构
[1] LUND INST TECHNOL, DEPT ELECT MEASUREMENTS, S-22007 LUND, SWEDEN
关键词
HYPERTHERMIA; THERMOMETRY; ELECTRICAL IMPEDANCE TOMOGRAPHY;
D O I
10.3109/02656739209052877
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The objective of this study is a non-invasive assessment of the thermal dose in hyperthermia. Electrical impedance tomography (EIT) has previously been given a first trial as a temperature monitoring method together with microwave-induced hyperthermia treatment, but it has not been thoroughly investigated. In the present work we have examined this method in order to investigate the correlation in vitro between the true spatial temperature distribution and the corresponding measured relative resistivity changes. Different hyperthermia techniques, such as interstitial water tubings, microwave-induced, laser-induced and ferromagnetic seeds have been used. The results show that it is possible to find a correlation between the measured temperature values and the tomographically measured relative resistivity changes in tissue-equivalent phantoms. But the uncertainty of the temperature coefficients, which has been observed, shows that the method has to be improved before it can be applied to clinical in vivo applications.
引用
收藏
页码:33 / 43
页数:11
相关论文
共 20 条
  • [1] Quantitative assessment of impedance tomography for temperature measurements in microwave hyperthermia
    Amasha, H.M.
    Anderson, A.P.
    Conway, J.
    Barber, D.C.
    [J]. Clinical Physics and Physiological Measurement, 1988, 9 (SUPPL. A): : 49 - 53
  • [2] APPLIED POTENTIAL TOMOGRAPHY
    BARBER, DC
    BROWN, BH
    [J]. JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1984, 17 (09): : 723 - 733
  • [3] BLAD B, 1990, 191 LUND I TECHN DEP
  • [4] BLAD B, 1991, ACTA RADIOLOGICA, V32
  • [5] TEMPERATURE DISTRIBUTIONS IN TUMOR-MODELS HEATED BY SELF-REGULATING NICKEL COPPER ALLOY THERMOSEEDS
    BREZOVICH, IA
    ATKINSON, WJ
    CHAKRABORTY, DP
    [J]. MEDICAL PHYSICS, 1984, 11 (02) : 145 - 152
  • [6] Brown B H, 1987, Clin Phys Physiol Meas, V8 Suppl A, P91, DOI 10.1088/0143-0815/8/4A/012
  • [7] TEMPERATURE-DEPENDENCE OF COMPUTED-TOMOGRAPHY ATTENUATION VALUES
    BYDDER, GM
    KREEL, L
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1979, 3 (04) : 506 - 510
  • [8] CHRISTENSEN DA, 1983, HYPERTHERMIA CANCER, P223
  • [9] Conway J, 1987, Clin Phys Physiol Meas, V8 Suppl A, P141, DOI 10.1088/0143-0815/8/4A/018
  • [10] FALLONE BG, 1982, MED PHYSICS, V9