PULSATILE FLOW ARTIFACTS IN 2-DIMENSIONAL TIME-OF-FLIGHT MR-ANGIOGRAPHY - INITIAL STUDIES IN ELASTIC MODELS OF HUMAN CAROTID ARTERIES

被引:11
作者
BUXTON, RB
KERBER, CW
FRANK, LR
机构
[1] Department of Radiology, University of California at San Diego Medical Center, San Diego, California, 92103
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 1993年 / 3卷 / 04期
关键词
ARTIFACT; BLOOD; FLOW DYNAMICS; CAROTID ARTERIES; MATHEMATICAL MODEL; PHANTOMS; VASCULAR STUDIES;
D O I
10.1002/jmri.1880030412
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Initial experimental and numerical analysis of artifacts due to pulsatile flow in two-dimensional time-of-flight (2D-TOF) magnetic resonance (MR) angiography are presented. The experimental studies used elastic models of the carotid artery bifurcation cast from fresh cadavers and accurately reproducing the twisting and tapering of the human blood vessels, allowing direct comparison of images with and without flow. Prominent image artifacts, including periodic ghosts and signal loss, were produced by pulsatile flow even though flow-compensated gradient waveforms were used. The dependence of artifacts due to partial saturation on pulse sequence parameters (TR and flip angle) was investigated theoretically for a simple pulsatile velocity profile and compared with experimental results from a model of a normal carotid artery. Signal reduction was observed proximal and distal to the stenosis in a model with a 70% internal carotid artery (ICA) stenosis and a model with 90% stenoses in both the ICA and the external carotid artery. Although this study deals exclusively with 2D-TOF imaging, the methods can also be applied to evaluate other MR angiography techniques.
引用
收藏
页码:625 / 636
页数:12
相关论文
共 30 条
[1]  
Nishimura DG, Macovski A, Pauly JM, Magnetic resonance angiography, IEEE Transactions on Medical Imaging, 5 MI, pp. 140-151, (1986)
[2]  
Gullberg GT, Wehrli FW, Shimakawa A, Simons MA, MR vascular imaging with a fast gradient refocusing pulse sequence and reformatted images from transaxial sections, Radiology, 165, pp. 241-246, (1987)
[3]  
Keller PJ, Drayer BP, Fram EK, Et al., MR angiography with two‐dimensional acquisition and three‐dimensional display: work in progress, Radiology, 173, pp. 527-532, (1989)
[4]  
Listerud J, First principles of magnetic resonance angiography, Magn Reson Q, 7, pp. 136-170, (1991)
[5]  
Pelc NJ, Herfkens RJ, Shimakawa A, Enzmann DR, Phase contrast cine magnetic resonance imaging, Magn Reson Q, 7, pp. 229-254, (1991)
[6]  
Rittgers SE, Fei DY, Kraft KA, Fatouras PP, Kishore PRS. Velocity profiles in stenosed tube models using magnetic resonance imaging, J Biomech Eng, 110, pp. 180-184, (1988)
[7]  
Kraft KA, Fatouros PP, Fei DY, Rittgers SE, Kishore PRS, MR imaging of model fluid velocity profiles, Magn Reson Imaging, 7, pp. 69-77, (1989)
[8]  
Podolak MJ, Hedlund LW, Evans AJ, Herfkens RJ, Evaluation of flow through simulated vascular stenoses with gradient echo magnetic resonance imaging, Invest Radiol, 24, pp. 184-189, (1989)
[9]  
Fei DY, Kraft KA, Fatouros PP, Model studies of nonsteady flow using magnetic resonance imaging, J Biomech Eng, 112, pp. 93-99, (1990)
[10]  
Krug B, Kugel H., Friedmann G, Et al., MR imaging of poststenotic flow phenomena: experimental studies, JMRI, 1, pp. 585-591, (1991)