PINHOLE COLLIMATION FOR ULTRA-HIGH-RESOLUTION, SMALL-FIELD-OF-VIEW SPECT

被引:251
作者
JASZCZAK, RJ [1 ]
LI, JY [1 ]
WANG, HL [1 ]
ZALUTSKY, MR [1 ]
COLEMAN, RE [1 ]
机构
[1] DUKE UNIV,DEPT BIOMED ENGN,DURHAM,NC 27708
关键词
D O I
10.1088/0031-9155/39/3/010
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The objective of this investigation was to evaluate small-field-of-view, ultra-high-resolution pinhole collimation for a rotating-camera SPECT system that could be used to image small laboratory animals. Pinhole collimation offers distinct advantages over conventional parallel-hole collimation when used to image small objects. Since geometric sensitivity increases markedly for points close to the pinhole, small-diameter and high-magnification pinhole geometries may be useful for selected imaging tasks when used with large-field-of-view scintillation cameras. The use of large magnifications can minimize the loss of system resolution caused by the intrinsic resolution of the scintillation camera. A pinhole collimator has been designed and built that can be mounted on one of the scintillation cameras of a triple-head SPECT system. Three pinhole inserts with approximate aperture diameters of 0.6, 1.2 and 2.0 mm have been built and can be mounted individually on the collimator housing. When a ramp filter is used with a three-dimensional (3D) filtered backprojection (FBP) algorithm, the three apertures have in-plane SPECT spatial resolutions (FWHM) at 4 cm of 1.5, 1.9 and 2.8 mm, respectively. In-air point source sensitivities at 4 cm from the apertures are 0.9, 2.6 and 5.7 counts s(-1) mu Ci(-1) (24, 70 and 154 counts s(-1) MBq-(1)) for the 0.6, 1.2 and 2.0 mm apertures, respectively. In vitro image quality was evaluated with a micro-cold-rod phantom and a micro-Defrise phantom using both the 3D FBP algorithm and a 3D maximum likelihood-expectation maximization (ML-EM) algorithm. In vivo image quality was evaluated using two (315 and 325 g) rats. Ultra-high-resolution pinhole SPECT is an inexpensive and simple approach for imaging small animals that can be used with existing rotating-camera SPECT system.
引用
收藏
页码:425 / 437
页数:13
相关论文
共 27 条
[1]  
ANGER H, 1967, INSTRUM NUCL, V1, P516
[2]  
BARRETT HH, 1981, RADIOLOGICAL IMAGING, P124
[3]  
BUDINGER TF, 1980, J NUCL MED, V21, P579
[4]  
CLACK R, 1991, 12TH INF PROC MED IM
[5]  
ERLANDSSON K, 1993, J NUCL MED, V34, pP9
[6]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[7]  
Grangeat P, 1990, MATH METHODS TOMOGRA
[8]  
ISHIZU K, 1993, J NUCL MED, V34, pP194
[9]   PHYSICAL FACTORS AFFECTING QUANTITATIVE MEASUREMENTS USING CAMERA-BASED SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY (SPECT) [J].
JASZCZAK, RJ ;
COLEMAN, RE ;
WHITEHEAD, FR .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1981, 28 (01) :69-80
[10]  