IMPLANTATION OF A SUBCUTANEOUS LEAD ARRAY IN COMBINATION WITH A TRANSVENOUS DEFIBRILLATION ELECTRODE VIA A SINGLE INFRACLAVICULAR INCISION

被引:10
作者
KALL, JG
KOPP, D
LONCHYNA, V
BLAKEMAN, B
CADMAN, C
OCONNOR, M
KINDER, C
GILKERSON, J
AVERY, R
WILBER, D
机构
[1] LOYOLA UNIV,MED CTR,DEPT MED,CARDIOL SECT,ELECTROPHYSIOL LAB,MAYWOOD,IL 60153
[2] LOYOLA UNIV,MED CTR,DEPT CARDIOTHORAC SURG,MAYWOOD,IL 60153
[3] CARDIAC PACEMAKERS INC,ST PAUL,MN
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1995年 / 18卷 / 03期
关键词
TRANSVENOUS DEFIBRILLATION; NONTHORACOTOMY DEFIBRILLATION; IMPLANTABLE CARDIOVERTER DEFIBRILLATOR; VENTRICULAR FIBRILLATION; SUBCUTANEOUS DEFIBRILLATION ELECTRODE;
D O I
10.1111/j.1540-8159.1995.tb02550.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Occasional patients have excessive defibrillation energy requirements despite appropriate transvenous defibrillation lead position and modification of defibrillation waveform and configuration. Preliminary data suggest that use of subcutaneous defibrillation electrode arrays with nonthoracotomy systems is associated with a substantial reduction in defibrillation threshold. The current operative approach to subcutaneous lead array implantation involves the use of a separate left chest incision. We present two cases in which implantation of a subcutaneous lead array in combination with a transvenous defibrillation electrode was performed via a single infraclavicular incision and associated with a reduction in defibrillation threshold. Such an approach simplities implantation and avoids the potential morbidity of the additional incision required of a left interal chest approach.
引用
收藏
页码:482 / 485
页数:4
相关论文
共 16 条
[1]   USE OF MULTIPLE PATCHES DURING IMPLANTATION OF EPICARDIAL DEFIBRILLATOR SYSTEMS [J].
BAERMAN, JM ;
BLAKEMAN, BP ;
OLSHANSKY, B ;
KOPP, DE ;
KALL, JG ;
WILBER, DJ .
AMERICAN JOURNAL OF CARDIOLOGY, 1993, 71 (01) :68-71
[2]  
BAKER JH, 1994, J AM COLL CARDIOL, V23, pA111
[3]   IMPLANTABLE TRANSVENOUS CARDIOVERTER-DEFIBRILLATORS [J].
BARDY, GH ;
HOFER, B ;
JOHNSON, G ;
KUDENCHUK, PJ ;
POOLE, JE ;
DOLACK, GL ;
GLEVA, M ;
MITCHELL, R ;
KELSO, D .
CIRCULATION, 1993, 87 (04) :1152-1168
[4]   A MODEL TO EVALUATE ALTERNATIVE METHODS OF DEFIBRILLATION THRESHOLD DETERMINATION [J].
CHURCH, T ;
MARTINSON, M ;
KALLOK, M ;
WATSON, W .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (11) :2002-2007
[5]  
ELLIS JR, 1994, PACE, V17, P742
[6]  
HIGGINS SL, 1994, PACE, V17, P784
[7]   A SUBCUTANEOUS LEAD ARRAY FOR IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS [J].
JORDAENS, L ;
VERTONGEN, P ;
VANBELLEGHEM, Y .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1993, 16 (07) :1429-1433
[8]  
KENKNIGHT BH, 1994, PACE, V17, P815
[9]  
KENKNIGHT BH, 1994, J AM COLL CARDIOL, V23, pA84
[10]  
LEVINE J, 1994, PACE, V17, P870