FAST ANGIOGRAPHY USING SELECTIVE INVERSION RECOVERY

被引:22
作者
WANG, SJ
NISHIMURA, DG
MACOVSKI, A
机构
[1] Magnetic Resonance Systems Research Laboratory, Stanford University, Stanford, California
关键词
D O I
10.1002/mrm.1910230112
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We have developed an enhancement of selective inversion recovery that allows us to obtain high‐resolution angiograms in reduced Scan time. By applying several read pulses following each tagging inversion pulse, we can obtain several phase encodes in each cardiac cycle, thereby reducing the total scan time required for a complete image. Using this technique, high‐resolution angiograms can be obtained in as little as 15 s. Because the phase encodes are collected in short bursts separated by long pauses, care must be taken to maintain uniform signal weighting across phase‐encoding views and avoid ghosting. We use an increasing flip‐angle sequence to equalize signal level weighting across the readouts. The phase encodes are collected in a special order to minimize ghosting. A postprocessing technique is used to further reduce signal nonuniformity between phase encodes. This fast angiography technique can significantly reduce artifacts due to patient motion during scanning and is especially useful for imaging vasculature in regions of the body where respiratory motion is a problem. © 1992 Academic Press, Inc. Copyright © 1992 Wiley‐Liss, Inc., A Wiley Company
引用
收藏
页码:109 / 121
页数:13
相关论文
共 10 条
[1]   RESPIRATORY ORDERED PHASE ENCODING (ROPE) - A METHOD FOR REDUCING RESPIRATORY MOTION ARTIFACTS IN MR IMAGING [J].
BAILES, DR ;
GILDERDALE, DJ ;
BYDDER, GM ;
COLLINS, AG ;
FIRMIN, DN .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (04) :835-838
[2]  
HAACKE E M, 1986, Magnetic Resonance Imaging, V4, P359, DOI 10.1016/0730-725X(86)91046-5
[3]   SNAPSHOT FLASH MRI - APPLICATIONS TO T1, T2, AND CHEMICAL-SHIFT IMAGING [J].
HAASE, A .
MAGNETIC RESONANCE IN MEDICINE, 1990, 13 (01) :77-89
[4]   FLOW-COMPENSATED LIMITED FLIP ANGLE MR ANGIOGRAPHY [J].
LEE, JN ;
RIEDERER, SJ ;
PELC, NJ .
MAGNETIC RESONANCE IN MEDICINE, 1989, 12 (01) :1-13
[5]  
MEYER C, 1989, 8TH P SOC MAGN RES M, P362
[6]   MAGNETIC-RESONANCE ANGIOGRAPHY BY SELECTIVE INVERSION RECOVERY USING A COMPACT GRADIENT ECHO SEQUENCE [J].
NISHIMURA, DG ;
MACOVSKI, A ;
JACKSON, JI ;
HU, RS ;
STEVICK, CA ;
AXEL, L .
MAGNETIC RESONANCE IN MEDICINE, 1988, 8 (01) :96-103
[7]   SELECTIVE SPIN INVERSION IN NUCLEAR MAGNETIC-RESONANCE AND COHERENT OPTICS THROUGH AN EXACT SOLUTION OF THE BLOCH-RICCATI EQUATION [J].
SILVER, MS ;
JOSEPH, RI ;
HOULT, DI .
PHYSICAL REVIEW A, 1985, 31 (04) :2753-2755
[8]   FAST LIMITED FLIP ANGLE MR SUBTRACTION ANGIOGRAPHY [J].
TASCIYAN, TA ;
LEE, JN ;
RIEDERER, SJ ;
DECASTRO, JB ;
HEDLUND, LW ;
HERFKENS, RJ ;
SPRITZER, CE .
MAGNETIC RESONANCE IN MEDICINE, 1988, 8 (03) :261-274
[9]  
WANG S, 1989, 75TH RSNA SCI PROGR, V173, P412
[10]   MULTIPLE-READOUT SELECTIVE INVERSION RECOVERY ANGIOGRAPHY [J].
WANG, SJ ;
NISHIMURA, DG ;
MACOVSKI, A .
MAGNETIC RESONANCE IN MEDICINE, 1991, 17 (01) :244-251