NEW TECHNIQUE FOR IMPROVING HEMOSTASIS IN AORTIC ROOT REPLACEMENT WITH COMPOSITE GRAFT

被引:37
作者
COPELAND, JG
ROSADO, LJ
SNYDER, SL
机构
[1] Department of Cardiovascular and Thoracic Surgery, University Medical Center, Tucson, AZ
关键词
D O I
10.1016/0003-4975(93)90146-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
By using both aortic annular and supraannular aortic wall tandem suture lines, we have, in our experience, markedly improved hemostasis in aortic root replacement with composite conduits of two types. Using this technique, 4 of 5 patients required 2 units or less of transfused red blood cells. Two patients did not receive transfusions. The technique consists of using interrupted mattress sutures to anchor the lower part of the valve sewing ring to the aortic annulus. The upper part of the sewing ring is then anchored with a running suture line to the cut edge of the supraannular aortic wall.
引用
收藏
页码:1027 / 1029
页数:3
相关论文
共 15 条
[1]  
ABLAZA SGG, 1978, J THORAC CARDIOV SUR, V76, P390
[2]   A TECHNIQUE FOR COMPLETE REPLACEMENT OF ASCENDING AORTA [J].
BENTALL, H ;
DEBONO, A .
THORAX, 1968, 23 (04) :338-&
[3]  
CABROL C, 1986, J THORAC CARDIOV SUR, V91, P17
[4]  
Cabrol C, 1988, J Card Surg, V3, P167, DOI 10.1111/j.1540-8191.1988.tb00237.x
[5]  
CABROL C, 1981, J THORAC CARDIOV SUR, V81, P309
[6]   COMPOSITE VALVE-GRAFT REPLACEMENT OF AORTIC ROOT USING SEPARATE DACRON TUBE FOR CORONARY-ARTERY REATTACHMENT [J].
COSELLI, JS ;
CRAWFORD, ES .
ANNALS OF THORACIC SURGERY, 1989, 47 (04) :558-565
[7]  
EMERY RW, AORTIC VALVE, P235
[8]  
GUILMET D, 1979, J THORAC CARDIOV SUR, V77, P516
[9]   LEFT-TO-RIGHT SHUNTS IN CONTROL OF BLEEDING FOLLOWING SURGERY FOR ANEURYSMS OF THE ASCENDING AORTA [J].
HOOVER, EL ;
HSU, HK ;
ERGIN, A ;
KETOSUGBO, A ;
WEBB, H ;
KHARMA, B ;
GRIEPP, RB .
CHEST, 1987, 91 (06) :844-849
[10]  
KLOPP E, 1978, SURGERY, V84, P292