The determination of cadmium by electrothermal atomization atomic absorption spectrometry with a platinum tube atomizer in the presence of air has been investigated. The detection limit of cadmium was 0.09 pg (9 pg/ml for a 10-mu-l volume). The relative standard deviation of the measurement was 2.9%. For 2.5 pg of cadmium, Cu, Pb, Zn, Al, Ca, Fe, K, Mg and Na (10(4)-10(5)-fold) did not interfere with the absorption signal. The method has been applied to the determination of cadmium in some biological materials. The average analytical value found for the standards lay within the limits of the certified values. The remarkable merits of the platinum atomizer are its stability in air and long life-time (able to withstand more than 1000 heating cycles in air).
引用
收藏
页码:871 / 874
页数:4
相关论文
共 20 条
[1]   SYNTHETIC REFERENCE MATERIAL FOR DIRECT ANALYSIS OF SOLID BIOLOGICAL SAMPLES BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY [J].
AKATSUKA, K ;
ATSUYA, I .
ANALYTICAL CHEMISTRY, 1989, 61 (03) :216-220
[2]   SIMPLE LOW-COST TUNGSTEN-COIL ATOMIZER FOR ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY [J].
BERNDT, H ;
SCHALDACH, G .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (05) :709-712
[3]   IMPROVEMENTS IN LOOP ATOMIC-ABSORPTION SPECTROMETRY BY APPLICATION OF AN IRIDIUM LOOP AND A CERAMIC COLLECTION TUBE [J].
BERNDT, H ;
MESSERSCHMIDT, J .
ANALYTICA CHIMICA ACTA, 1982, 136 (APR) :407-411
[4]  
BERNDT H, 1982, J CLIN CHEM CLIN BIO, V20, P85
[5]  
BERNDT H, 1981, ATOMSPEKTROM SPURENA, P411
[6]  
BRANDENB.H, 1968, CHIMIA, V22, P449
[7]   METAL-OXIDE CLOTHS AS CHARRING ATOMIZATION SURFACES IN FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
BRUEGGEMEYER, TW ;
BONNIN, CA .
ANALYTICAL CHEMISTRY, 1988, 60 (08) :761-766
[8]  
CHEN SY, 1988, FENXI CESHI TONGBAO, V7, P56
[9]   ELECTROTHERMAL ATOMIZATION ATOMIC-ABSORPTION SPECTROMETRY WITH STABILIZED AQUEOUS STANDARDS FOR THE DETERMINATION OF CADMIUM IN WHOLE-BLOOD [J].
DEBENZO, ZA ;
FRAILE, R .
ANALYTICA CHIMICA ACTA, 1990, 231 (02) :283-288
[10]   DIRECT DETERMINATION OF CADMIUM IN URINE USING GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY WITH ZEEMAN-EFFECT BACKGROUND CORRECTION [J].
DUBE, P ;
KRAUSE, C ;
WINDMULLER, L .
ANALYST, 1989, 114 (10) :1249-1253