MULTIVESSEL PTCA USING THE HUGGING BALLOON TECHNIQUE BASED ON SINGLE GUIDE CATHETER AND DUAL BALLOON-ON-A-WIRE SYSTEMS

被引:6
作者
YOSHIDA, S
YABE, Y
NAKANO, H
MURAMATSU, T
NOIKE, H
机构
[1] Cardiovascular Diagnostic Laboratory Center, Toho University School of Medicine, Tokyo
来源
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS | 1991年 / 23卷 / 01期
关键词
CORONARY ANGIOPLASTY; LARGE CORONARY ARTERIES; DILATION;
D O I
10.1002/ccd.1810230111
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
For percutaneous transluminal coronary angioplasty (PTCA) of oversized arteries, often-times a satisfactory dilatation cannot be achieved with conventional balloon systems due to the unavailability of adequately sized balloons. This fact has contributed to a higher restenosis rate for this group of patients. We were able to obtain a satisfactory dilatation result in an oversized right coronary artery with a shepherd's crook configuration and eccentric anatomy at the origin using two balloon-on-a-wire systems and an Amplatz type guiding catheter. Although such favorable dilatation of an oversized artery using this "hugging balloon technique" can be expected, issues do exist such as difficult maneuverability and estimation of the balloon size obtained through simultaneous dual balloon inflation wherein size does not simply equal the sum of the two balloon catheters. It is hoped that there will be further improvements of the technique and development of new systems. At this time, however, it is felt that this is the most effective and reasonable strategy to achieve a high chance of success in oversized vessel lesions.
引用
收藏
页码:37 / 41
页数:5
相关论文
共 17 条
[1]   PERCUTANEOUS TRANS-LUMINAL ANGIOPLASTY OF STENOTIC CORONARY-ARTERY BYPASS GRAFTS - 5 YEARS EXPERIENCE [J].
COTE, G ;
MYLER, RK ;
STERTZER, SH ;
CLARK, DA ;
FISHMANROSEN, J ;
MURPHY, M ;
SHAW, RE .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 9 (01) :8-17
[2]  
DUPRAT G, 1984, CIRCULATION, V70, P11
[3]   PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY - THE 2ND-DECADE [J].
KING, SB .
AMERICAN JOURNAL OF CARDIOLOGY, 1988, 62 (18) :K2-K6
[4]  
MAYO GJ, 1989, CATHET CARDIOVASC DE, V27, P87
[5]   THE BALLOON ON A WIRE DEVICE - A NEW ULTRA-LOW-PROFILE CORONARY ANGIOPLASTY SYSTEM CONCEPT [J].
MYLER, RK ;
MOONEY, MR ;
STERTZER, SH ;
CLARK, DA ;
HIDALGO, BO ;
FISHMAN, J .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1988, 14 (02) :135-140
[6]   CORONARY BIFURCATION STENOSES - THE KISSING BALLOON PROBE TECHNIQUE VIA A SINGLE GUIDING CATHETER [J].
MYLER, RK ;
MCCONAHAY, DR ;
STERTZER, SH ;
JOHNSON, W ;
CUMBERLAND, DC ;
BOUCHER, RA ;
HIDALGO, B .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1989, 16 (04) :267-278
[7]   DOUBLE-WIRE ANGIOPLASTY OF THE RIGHT CORONARY-ARTERY BIFURCATIONAL STENOSIS [J].
NATH, A ;
VETROVEC, GW ;
COWLEY, MJ ;
NEWTON, M ;
DISCIASCIO, G ;
MUKHARJI, J ;
LEWIS, SA .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1988, 14 (01) :37-40
[8]   IMPORTANCE OF BALLOON SIZE IN CORONARY ANGIOPLASTY [J].
NICHOLS, AB ;
SMITH, R ;
BERKE, AD ;
SHLOFMITZ, RA ;
POWERS, ER .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 13 (05) :1094-1100
[9]   ANGIOPLASTY FOR DILATATION OF COMPLEX CORONARY-ARTERY BIFURCATION STENOSES [J].
PINKERTON, CA ;
SLACK, JD ;
VANTASSEL, JW ;
ORR, CM .
AMERICAN JOURNAL OF CARDIOLOGY, 1985, 55 (13) :1626-1628
[10]   INFLUENCE OF BALLOON SIZE ON INITIAL SUCCESS, ACUTE COMPLICATIONS, AND RESTENOSIS AFTER PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY - A PROSPECTIVE RANDOMIZED STUDY [J].
ROUBIN, GS ;
DOUGLAS, JS ;
KING, SB ;
LIN, S ;
HUTCHISON, N ;
THOMAS, RG ;
GRUENTZIG, AR .
CIRCULATION, 1988, 78 (03) :557-565